Digital Security Controls Ltd. 17LE4010 User Manual

Page of 35
16
OUTPUT 3: Power Supply or Battery Trouble - Output is normally high and switches to ground when a
problem with the power source is detected.
OUTPUT 4: General Module Trouble - Output is normally low and switches to high when a Cellular Net-
work Trouble, Power Supply/Battery Trouble, and/or a Failure to Communicate (FTC) trouble is detected.
Note: PGM4 must be connected to the control panel as shown in Figure 4 (Residential applications) or Figures
8-9 (Commercial applications). Program the control panel input Zone/Point as 24hr ‘Supervisory’ with keypad-
only notification when activated. Output 4 on the 3G4010/LE4010 must be set as ‘Active High’.
Note: Once an output has been activated automatically, it will not restore until all the causes of activation are
cleared.
6.6 Reporting Codes
3G4010/LE4010 Reporting Codes CID
SIA
Programmable Comments
Zone 1 Activation
E11A 991
FA 991
YES
Delayed 24 Hour Fire *
Zone 1 Restoral
R11A 991
FH 991
YES
Delayed 24 Hour Fire Restore *
Zone 2 Activation
E12A 992
PA 992
YES
Panic Alarm *
Zone 2 Restoral
R12A 992
PH 992
YES
Panic Alarm Restore*
Zone 3 Activation
E13A 993
BA 993
YES
Burglary *
Zone 3 Restoral
R13A 993
BH 993
YES
Burglary Restore *
Zone 4 Activation
E3AA 994
YX 994
YES
System Trouble *
Zone 4 Restoral
R3AA 994
YZ 994
YES
System Trouble Restore *
PSTN Line Down
E351 000
LT 000
FIXED
Telco 1 Fault
PSTN Line Restoral
R351 000
LR 000
FIXED
Telco 1 Fault Restore
Input Loss
E337 000
YP 000
FIXED
Power Supply Trouble
Input Restoral
R337 000
YQ 000
FIXED
Power Supply Trouble Restore
Low Battery Alert
E338 000
YT 000
FIXED
Transmitter Battery Trouble
Low Battery Restoral
R338 000
YR 000
FIXED
Transmitter Battery Restore
Periodic Test
E603 XXX RP XXX
FIXED
Test Transmission <Receiver Path>
Periodic Test with Trouble
E608 XXX RY XXX FIXED
Test Transmission <Receiver Path>
Radio Activation
R552 000
RS 000
FIXED
Remote Programming Successful
Internal Buffer Full
E624 000
JL 000
FIXED
FTC Restoral
R354 000
YK 000
FIXED
Communications Restored
Firmware Update Successful
R901 000
LS 000
FIXED
Firmware Update Fail
E902 000
LU 000
FIXED
Firmware Update Begin
E901 000
LB 000
FIXED
System Tamper
E145 000
ES 000
FIXED
Expansion Module Tamper
System Tamper Restore
R145 000
EJ 000
FIXED
Expansion Module Tamper Restore
* C24 Communications default value
6.7 Swinger Shutdown
To prevent "runaway" signals to the central station, the 3G4010/LE4010 is equipped with Swinger Shutdown
which limits certain trouble events to a maximum of four reports every 24 hours. The condition restores and
the counter resets at midnight. Swinger Shutdown applies to the following trouble conditions:
3G4010/LE4010 Installation Manual