Digital Security Controls Ltd. 17LE4010 User Manual

Page of 35
17
6.8 Hardware Default
l
System Tamper/Restore
l
Low Battery Trouble/Restore
l
TLM Trouble/Restore
l
Input Power Trouble/Restore
l
FTC Restore
6.8 Hardware Default
A hardware default updates the unit with the latest configuration from C24 Communications if:
l
The device was originally programmed incorrectly.
l
The unit was installed at a different location and then relocated to a new site.
l
A SIM card is being swapped.
To perform a hardware default, follow these steps:
1. Power down the unit (remove primary DC power and remove the backup battery) and remove all con-
nections to Zone1, Zone 2, PGM1 and PGM.
2. Connect a wire between Z2 (terminal 14) and PGM2 (terminal 8)or Z1 (terminal 13) and PGM1 (ter-
minal 7).
3. Power up the radio by connecting the battery (if present) first and then primary DC power.
4. Wait for 20 seconds and then completely power down the unit.
5. Disconnect the wire between the Zone and PGM terminals.
Note: Failure to perform hardware default will result in the unit transmitting with the previously programmed
configuration.
6.9 Communicator Reset/Update
The firmware of the device can be updated over Cellular or PC-Link:
l
When the firmware update begins, all LED are ON.
RED
BLUE
Yellow/Green
(Top)
Yellow/Green
(Bottom)
ON
ON
ON
ON
l
During the firmware update process the LEDs are cycled individually in a chaser pattern. (different from
the Advanced Carrier Selection pattern).
RED
BLUE
Yellow/Green
(Top)
Yellow/Green
(Bottom)
FLASH ON
OFF
OFF
OFF
OFF
FLASH ON
OFF
OFF
OFF
OFF
FLASH ON
OFF
OFF
OFF
OFF
FLASH ON
FLASH ON
OFF
OFF
OFF
OFF
FLASH ON
OFF
OFF
OFF
OFF
FLASH ON
OFF
OFF
OFF
OFF
FLASH ON
l
After a successful update, the unit automatically restarts.
Note: Several resets take place during a single Firmware update session.