NOTE: Minimum value is 000005 minutes. Programming an interval that is less than 5 minutes will dis-
able test transmission.
Cellular Receiver 1 Options
[201] Cellular Receiver 1 Account Code
Default (0000000000)
The account code is used by the central station to distinguish between transmitters. This account code is
used when transmitting heartbeat signals to the central station receiver. Signals received from the con-
trol panel will use the control panel account number. Valid range: 0000000001 - FFFFFFFFFE. Pro-
gramming all 0’s or all F’s will cause a module configuration trouble (yellow LED = 12 flashes).
[202] Cellular Receiver 1 DNIS
Default (000000)
The DNIS is used in addition to the account code to identify the communicator module at the central sta-
tion. Valid range: 000000 - 099999. Values are entered as a leading 0 followed by the five digit DNIS.
NOTE: Each Ethernet/cellular receiver must be programmed with a unique DNIS.
[203] Cellular Receiver 1 Address
Default (000.000.000.000)
Enter the cellular receiver 1 IP address. This information will be provided by the central station system
administrator. Each 3-digit segment of the address must be within a valid range of 000-255.
NOTE: When a valid IP address has been entered, the cellular receiver is enabled and will communicate
events over the cellular channel.
[204] Cellular Receiver 1 Port
Default (0BF5/3061)
This section determines the port used by cellular receiver 1. Change the default value of this port when
the installation is located behind a firewall and must be assigned a particular port number as determined
by the central station system administrator. Valid range: 0000 - FFFF.
NOTE: Programming this section with 0000 will disable the receiver.
[205] Cellular Receiver 1 APN
Default ()
The Access Point Name (APN) determines the cellular network that the communicator will connect to.
This information is available from the network carrier. Program this section as 32 ASCII characters.
NOTE: When a SIM card with a custom APN is used, the unit will not have access to the Internet. DLS
and remote flash can still be done if section [221] is programmed with a valid public APN.
[206] Cellular Receiver 1 Domain Name
Default (  )
Enter the Domain Name as 32 ASCII characters. This information will be provided by the central station
system administrator.
Cellular Receiver 2 Options
[211] Cellular Receiver 2 Account Code
Default (0000000000)
The account code is used by the central station to distinguish between different transmitters. This
account code is used when transmitting signals to the central station receiver. Signals received on the
panel will use the panel account number. Valid range: 0000000001 - FFFFFFFFFE.
NOTE: Programming this section as all 0’s or F’s will cause a module configuration trouble (yellow LED =
12 flashes).
[212] Cellular Receiver 2 DNIS
Default (000000)
The DNIS is used in addition to the account code to identify the communicator module at the central sta-
tion. Valid range: 000000 - 099999. Values are entered as a 0 followed by the 5 digit DNIS value. Format
is BCD.
NOTE: Each Ethernet/cellular receiver must be programmed with a unique DNIS.
[213] Cellular Receiver 2 Address
Default (000.000.000.000)
Enter the cellular receiver 2 IP address. This IP address will be provided by the central station. Format is
4 fields, each field is 3-digit decimal. Valid range: 000 - 255.
NOTE: When a valid address has been entered, cellular receiver 2 is enabled and will communicate
events over the cellular path.