Digital Security Controls Ltd. 18LE2077 User Manual

Page of 51
14
NOTE: If required, download the DLS IV software from DSC: http://www.dsc.com. If you select 
Cellular connection, DLS will request Connect24 to send an outgoing SMS message to the 
unit.
2. Connect24 will confirm that the account has DLS service and will provide the Public IP
address and port number of the DLS server in an SMS message.
3. SMS message will establish a connection to your computer’s DLS IV software (to change
programming labels only).
4. Create an account for the panel/Communicator, select the Communicator type (e.g., SMS -
TL2553G) and enter all relevant information in SMS section.
NOTE: The Cellular telephone number will also be required by the user, to send SMS Command 
and Control messages to their system.
5. Program the account information, then click Global Download and choose SMS as the
Connection Type. Click OK.
6. The download path configured in Programming Section [005] Toggle Option[4]
determines the Cellular or Ethernet path to be used.
C
OMMUNICATOR
 P
LACEMENT
 T
EST
(LE2077/TL2553G only)
1. Using the keypad enter the installer mode: [*][8] [installer code] [850].
2. View and record the number of bars showing on the SCW LCD.
3. Compare with the number of bars indicated in the “CSQ Levels” column shown in Table 7 .4. If 3 or more bars are shown, the location is GOOD and no further action is required.
5. If the location is BAD, move the SCW to various suitable locations until 3 or more bars are
obtained.
NOTE: The communicator is capable of indicating signal strength even without an active SIM, 
but signal indication may take up to 1-2 minutes.
Domain Name Service (DNS) programming is not permitted in UL/ULC listed systems.
K
EYPAD
 D
ATA
 D
ISPLAY
• Section-Toggle Options: The number is displayed when Toggle is ON. The number is not
displayed when  Toggle is OFF. (e.g., Toggle Options displays: “[--3--6--]”. Options 3 and 6
are ON, all others are OFF). Pressing keys 1 through 8 will alternately turn the Toggle ON and
OFF.
• HEX/Decimal Data: Values that are provided with two defaults, separated by a / character,
use the format: hexadecimal followed by decimal equivalent (e.g., Default [0BF5/3061]).
Hexadecimal numbers are shown, with all leading zeroes, to the full field length defined for
the number.
E
NTERING
 D
ATA
 F
ROM
 K
EYPAD
To enter data at the keypad, press the number key, from the table below, to select the character 
that you want. Pressing the number key repeatedly will scroll through the characters available 
Table 7:  Communicator CSQ Levels
Signal 
Strength
CSQ Level
Signal Level 
dBm
Installer Action
No Signal
0
-108.8
Check if Cellular coverage is active in your area.
1 Bar
1 to 4
-108d to -103 Location is BAD. Not suitable for Cellular operation.
2 Bars
5 to 6
-102 to -99
3 Bars
7 to 10
-98d to -91
Location is GOOD.
4 Bars
11 to 13
-90 to -85
5 Bars
14 and higher -84 and higher
 G
ENERAL
 I