Digital Security Controls Ltd. 18LE2077 User Manual

Page of 51
18
OFF: When the periodic test transmission interval occurs, the test transmission will be sent to
the programmed receivers, based on the settings of the periodic test transmission reporting
codes.
[8] Cellular Low Signal Trouble.
Default (OFF)
This option masks the Low Signal trouble from the Cellular trouble event.
ON: A Cellular Trouble event is transmitted to receiver when the radio signal level falls below
threshold level (average CSQ level is 4 or less).
OFF: A Cellular Trouble event is not transmitted to receiver when the radio signal level falls
below threshold level (average CSQ level is 4 or less).
[006] System Toggle Options 2
[1] Ethernet 1 Receiver Enabled.
Default (ON) (OFF for LE2077).
ON: Ethernet Receiver 1 is enabled.
OFF: Ethernet Receiver 1 is disabled.
[2] Ethernet 2 Receiver Enabled.
Default (ON) (OFF for LE2077).
ON: Ethernet Receiver 2 is enabled.
OFF: Ethernet Receiver 2 is disabled.
[3] Reserved. ( ).
[4] Cellular 1 Receiver Enabled.
Default
 (ON).
ON: Cellular Receiver 1 is enabled. 
OFF: Cellular Receiver 1 is disabled.
[5] Cellular 2 Receiver Enabled.
Default
 (ON).
ON: Cellular Receiver 2 is enabled.
OFF: Cellular Receiver 2 is disabled.
[6] Reserved ( ).
[7] DLS Over Cellular.
Default (ON).
NOTE: Program this toggle as OFF if you want to completely disable DLS from using the Cellular 
path.
ON: DLS is enabled on the Cellular path.
OFF: DLS is disabled on the Cellular path.
NOTE: If this Toggle is OFF, DLS sessions will occur on the Ethernet path only, regardless of 
Primary Path set in Section [005] Toggle Option [4]. If it is ON then the Communicator will 
connect to the Primary path first for DLS and if the session fails, the Secondary path will be used.
[8] Trouble Suppression 
Default (OFF)
ON: GSM, Ethernet and Receiver Supervision Trouble and Restore conditions will be delayed for
the time period programmed in section [226]. After the delay expires the trouble conditions
will be indicated and communicated.
OFF: GSM, Ethernet and Receiver Supervision Troubles will be immediately indicated and
communicated.
[007] DNS Server IP 1
Default (000.000.000.000)
i
Programming this Section is not permitted on a UL/ULC listed system.
Enter the IP address for DNS Server 1. Format is 4 fields, each field is a 3 digit decimal. Valid
range: 000-255.