ADC Telecommunications Inc. PRSM070A User Manual

Page of 138
FlexWave-URH Agent MIB
FlexWave Prism Host, Remote and EMS 5.1 System Reference
Page 301
ADCP-77-073
  • Issue 2 • 11/2009
© 2009 ADC Telecommunications, Inc.
fwuRmtSERFOptOverDriveFaultMask
Trap enable/disable for SFP 
Over Drive Fault. Trap is 
enabled by default. If 
disabled, the trap will not be 
raised.
MASKType
SET
fwuRmtSERFOptUnderDriveFaultMask
Trap enable/disable for SFP 
Under Drive Fault; trap is 
enabled by default; if 
disabled, the trap will not be 
raised
MASKType
SET
fwuRmtSERFEthPortNumber
A unique identifier for each 
Ethernet port (from 1 to 12)
Unsigned32
GET
fwuRmtSERFEthPortType
An identifier for the type of 
Ethernet port
ENETType
GET
fwuRmtSERFEthPortRxBytes
Receive byte counter
Counter64
GET
fwuRmtSERFEthPortRxPkts
Receive packet counter
Counter64
GET
fwuRmtSERFEthPortRxFscErrors
Receive FCS error counter
Counter64
GET
fwuRmtSERFEthPortRxBroadcastPkts
Receive broadcast packet 
counter
Counter64
GET
fwuRmtSERFEthPortRxMulticastPkts
Receive multicast packet 
counter
Counter64
GET
fwuRmtSERFEthPortRxFragmtdFrames
Receive fragments counter
Counter64
GET
fwuRmtSERFEthPortRxJabbersFrames
Receive jabber counter
Counter64
GET
fwuRmtSERFEthPortTxByteCounter
Transmit byte counter
Counter64
GET
fwuRmtSERFEthPortTxPkts
Transmit packet counter
Counter64
GET
fwuRmtSERFEthPortTxBroadcastPkts
Transmit multicast packet 
counter
Counter64
GET
fwuRmtSERFEthPortTxMulticastPkts
Transmit broadcast packet 
counter
Counter64
GET
fwuRmtSERFEthSFPID
Identifier of SFP to which this 
Ethernet port connects to
Unsigned32
GET
fwuRmtDARTNumber
A unique identifier for each 
DART Card Object of Remote 
(from 1 to 8)
Integer32
GET
fwuRmtDARTName
A user defined name for each 
DART Card object of Remote, 
which can be up to 32 
characters
DisplayString
SET
fwuRmtDARTBandType
Band type of Remote DART 
card
BANDType
GET
Table 12-2.  FlexWave-URH Agent MIB GET/SET Objects (Cont.)
Object Name
Description
SNMP Syntax
Get 
or
SET