TransCore 05531 User Manual

Page of 278
4-3
Chapter 4
Installing the Encompass 4/4800 Multiprotocol
Reader
This chapter lists the materials needed and presents the procedures to 
pre-test and install the Encompass
TM
 4/4800 Multiprotocol Reader.
Installation Process
After you have developed the site plan and identified the location to install the 
Encompass 4/4800 Multiprotocol Reader and antenna
1
, if required, you are ready to 
install the equipment. Installation involves the following tasks:
Pre-installation testing of Encompass 4/4800 Multiprotocol Reader power and tag 
read capability
Mounting the Encompass 4/4800 Multiprotocol Reader and antenna, if required, 
on a pole, ceiling, or wall
Connecting the antenna
Connecting the Encompass 4/4800 Multiprotocol Reader power
Marking the read zone
Connecting the Encompass 4/4800 Multiprotocol host and sense input/sense out-
put and communications
Materials Supplied by TransCore
You need the following materials to pre-test and install the Encompass 4/4800 Multi-
protocol Reader. TransCore supplies some of the materials; other materials must be 
obtained from other sources.
Contents of Shipping Carton
Ensure that you have received all parts before beginning your pre-installation Encom-
pass 4/4800 Multiprotocol Reader tests. Your Encompass 4/4800 Multiprotocol 
Reader is packaged with the following materials:
One Encompass 4/4800 Multiprotocol Reader
1.
The Encompass 4/4800 Multiprotocol Reader is designed with an internal patch antenna 
or with a RF cable connector for use with an external antenna. Unless noted in the text, 