Rosslare Enterprises Ltd AYC-T65 User Manual

Page of 68
Wiring Instructions 
16 
AYC-Ex5 and AYC-T65 Installation and Programming Manual 
4.
 
Wiring Instructions 
The unit is supplied with a 60-inch (1.5 meter) pigtail, having a 6-
conductor cable. To connect the unit to the controller, perform the 
following: 
Prepare the unit's cable by cutting the cable jacket back 1¼ inches 
and strip the wire ½ inch. Prepare the controller cable by cutting the 
cable jacket back 1¼ inches and strip the wire ½ inch. 
Splice the unit’s pigtail wires to the corresponding controller wires 
and cover each connection. 
Refer to Table 1 and to the wiring diagrams provided on the following 
pages. 
Table 1: Wiring Colors 
Reader 
Controller  
Color  Functionality 
5~16 VDC 
5~16 VDC 
Red 
+DC Input 
Shield/Ground 
Shield/Ground 
Black 
Ground 
Data 1/Clock 
C 1 
White 
Communication 
Data 0/Data 
C 2 
Green 
Communication 
LEDCTL 
AUX. IN 
Brown  LED Control/Auxiliary Input 
Tamper 
Tamper 
Purple  Tamper 
If the tamper output is used, connect the purple wire to the correct 
input on the controller when used as a reader, or to a zone input of 
an intruder alarm system when used as a controller. 
Trim and cover all unused conductors.