GatesAir Inc. CZF User Manual

Page of 148
APEX
 Exciter Incorporating FLO
 Technology
Details of the Exciter Status Screens
Navigating the LCD Display Screens
26
04s30
0.fm
03/08/07
888-2604-001
Page: 3-21
WARNING: Disconnect primary power prior to servicing.
3.4.5.2.1 PLL Diagnostics
Refer to Figure 3-19. This screen is not used phase lock loop boards where the PLL Board
10 kHz Reference entry, shown in Figure 3-18, is labeled N/A. It is used for units where
the PLL Board 10 kHz Reference entry is labeled Yes.
The Xtal Aging (crystal oscillator aging) control is used to set the frequency of the internal
10 MHz crystal oscillator when no external reference is used. The initial setting should
typically be in the range of 3000 to 3500. 
PLLDiagnostics.bmp
Figure 3-19  PLL Diagnostics
3.4.5.3
Up Converter Board Status Screen
UpConverterStatus.bmp
Figure 3-20  Up Converter Board Status Screen
The exciter output amplifier does not have a separate screen. It parameters (+/-15 Vdc and
RF detector output) are included in this screen. The UDC Interface Board screen is shown
in Figure 3-20, with screen entries listed below.