GatesAir Inc. CZF User Manual

Page of 148
 
  
APEX
 Exciter Incorporating FLO
 Technology
Navigating the LCD Display Screens
Details of the System Setup Screens
Page: 3-48
888-2604-001
03/08/07
WARNING: Disconnect primary power prior to servicing.
3.6.7
FPGA Setup
The FPGA modulator setup is accomplished in the following nine screens.
3.6.7.1
FPGA Configure 1/5
FPGASetup1.bmp
Figure 3-40  FPGA Configure 1/5
FPGA Configure 1/5 consists of registers whose values are written immediately to the
FPGA when changed through the GUI. 
No FPGA re-initialization occurs when any of these registers are changed.
The parameters of the FPGA Configure 1/5 screen are as follows.
• Transmitter ID: (Unsigned 16-bit Decimal, range 0 to 65535)
• Wide Area PID: (Unsigned 13-bit Decimal, range 0 to 8191)
• Local Area PID: (Unsigned 13-bit Decimal, range 0 to 8191)
• TS Stream Control: (TS1 Active/TS2 Active)
• TS Source Control: (Automatic/Manual)
• Infrastructure ID: (Unsigned 16-bit Decimal, range 0 to 65535)
• Local Time Offset: (Signed Real Decimal in Hours, range -16.0 to +15.5 in 0.5 in-
crements  Register value is calculated as [Local Time Offset]*2)
• Daylight Savings: (Standard/Daylight)