APEX
 Exciter Incorporating FLO
 Technology
Details of the System Setup Screens
Navigating the LCD Display Screens
26
04s30
0.fm
03/08/07
888-2604-001
Page: 3-49
WARNING: Disconnect primary power prior to servicing.
3.6.7.2
FPGA Configure 2/5
FPGASetup2.bmp
Figure 3-41  FPGA Configure 2/5
FPGA Configure 2/5 consists of registers whose values are written immediately to the
FPGA when changed through the GUI and other software parameters.
No FPGA re-initialization occurs when these registers and parameters are changed.
The parameters of the FPGA Configure 2/5 screen are as follows.
• SFN Mode: Indication is On or Off
• SFN Limit: Software parameter, time in microseconds, range 0-999)
• 1PPS Mute Delay: Displayed in minutes, with a range 0 to 2000. 
When the GPS 1PPS signal loss (shown in the Main Screen > Status > Digital Pro-
cessing > FLO FPGA Registers > GPS and Clock Status screen) exceeds the 1PPS 
Mute Delay time, the GPS 1PPS Loss indication in the GPS and Clock Status screen 
will change to YES (in red) and cause the exciter to mute. 
• PRBS On/Off: Indication is On or Off
• TDM1 Null: Indication is On or Off. This register is not part of the initialization se-
quence.)
• FPGA Access has following functions: 
• From AC restart, the FPGA access mode is always enabled, but it can be dis-
abled at any time. 
• In the FPGA access disable mode: 
The periodic access to the FPGA will be blocked, except for flywheel and in-
ternal GPS.
FPGA will not be initialized by SW
LCD interface to FPGA is not blocked, the user must decide to decide to 
change the configuration from GUI.
The mute to exciter cannot be performed by SW since it now has no access 
to the FPGA.