Tyco Safety Products/Sensormatic AMS1140 User Manual

Page of 15
 
AMS-1140 DETECTORS 
8200-2684-02, REV. 0 
SETUP AND SERVICE GUIDE 
9 of 15
 
4.  Install the hole plug supplied in the pedestal 
installation kit in the conduit access hole that 
will not be used. 
5.  Install the steel conduit clamp supplied in the 
pedestal installation kit. 
 
WARNING!
 DO NOT run the power 
cable and the Interconnect cable in the 
same conduit or raceway. 
6.  Have a licensed electrician wire the primary 
pedestal to power. The locations of where the 
Line, Neutral, and Ground wires connect to the 
grounding plate are shown above. 
Tuning the Pedestals 
Tuning the pedestals is not a standard part of initial 
installation; the system should be left at the factory 
default setting of minimum capacitance (all 
jumpers out). If the pedestals are placed near a lot 
of metal, however, the current in the system may 
be reduced and the performance can be reduced. 
If the performance is unacceptable and the 
maximum burst current is not at least 30A, you can 
use the following procedure to optimize the tuning 
until maximum peak current is achieved.  
1.  Remove the base covers on both pedestals 
and locate the tuning jumpers on the main 
circuit board on the primary pedestal and the 
secondary capacitor board. See Figure 1. 
 
Primary tuning jumpers: J2, J3, J4 
 
Secondary tuning jumpers: J1, J2 
2.  Ensure the tuning jumpers are set to their 
default values. See Table 1 (primary) or 
Table 2 (secondary).  
3.  Adjust the tuning jumpers on the primary 
pedestal up one step (for example, from Step 
0 to Step 1).  
4.  Check the current. 
  If the current is less than before you adjust 
the capacitance, you are detuning the 
pedestal. Return to the default setting. You 
are done. 
  If the current goes up, you are tuning the 
pedestal in the correct direction. Keep 
adding capacitance until you find the peak 
current. 
5.  If you get to step 8 in Table 1 (all jumpers in) 
and the current is still increasing, go to the 
secondary pedestal and increase the 
capacitance one step. Then go back to the 
primary pedestal, set it back to step one (all 
jumpers removed) and start adding 
capacitance on the primary one step at a time. 
Table 1. AMS-1140 Tuning Table (Primary) 
Step # 
J4 
JW3  JW2 
1* 
*    Default  
Table 2. AMS-1140 Tuning Table (Secondary) 
Step # 
J2 
J1 
1* 
*    Default  
 
 
Line 
Neutral 
Ground