Park Air Systems Limited B6350 User Manual

Page of 73
TO VIEW BIT PAGES AND ADVISE SCREEN
Use the following procedure to view the BIT page displays. Note that after a BIT interruptive test, the BIT
screens are automatically displayed.
1.
From the Main screen, press the switch to
display the Options menu. Turn the switch
until BIT is highlighted. Press the switch.
2.
Ensure the BIT menu is displayed. Turn the
switch until BIT View is highlighted, then
press the switch.
3.
A series of pages is shown displaying
certain
transmitter
parameters.
Some
examples are shown here.
A full list of BIT screens along with
appropriate explanations is given in the
T6T transmitter maintenance handbook.
4.
Note that the last BIT screen allows Advise
to be highlighted and selected by pressing
the switch. If any BIT faults have been
detected, the advise screen recommends
the remedial action, in order of priority, to be
taken.
Further detail regarding the Advise screen
is given in the T6T transmitter maintenance
handbook.
Section 2
T6T AM-Voice Operation
Page 38
F r e q u e n c y
C h a n n e l
C o n f
i g u r e
B I T
E x i
t
B I T
I n i
t
i a t e
B I T
V i e w
B a c k
E x i
t
A C
S u p p l y
O N
D C
S u p p l y
O F F
S u p p l y
3 1 V
> >
Example BIT Screen
S y n t h
L o c k
P A S S
P A
T e m p
3 0 °
P A
T e m p
P A S S
< <
> >
Example BIT Screen
A d v i s e
B a c k
< <
Last BIT Screen
P l e a s e
C h e c k
1 : A n t e n n a
2 : P A
C t r l
.
Example Remedial Advise Screen