Table 2-2 Operational Settings
Parameter
Adjustment Range
Factory Default
Setting
Further Reference
Menu Lock screen
Locked or Unlocked
Unlocked
Page 20
To enter Standby mode
On or Off
Off
Page 23
To exit Standby mode
-
-
Page 24
Set mode of operation
AM voice
AM-voice
Part of AM Voice
Settings Procedure
starting on page 25.
PTT test facility
On or Off
Off
PTT timeout
2 s to 510 s, or off
180 s
Modulation depth
0 to 100%
85%
Tx mute
On or off
On
Vogad
On or Off
On
Carrier offset
0,
±
2.5,
±
4,
±
5,
±
7.3,
±
7.5, or
±
8 kHz
0 (no offset)
Adjust sidetone volume
0 to 100%
30%
Front panel frequency step size
8.33, 25 kHz, or both
25 kHz
LCD backlight timeout
15 s to 120 s, Off, or On
30 s
Part
of
General
Transmitter Settings
starting on page 29.
PTT inhibit
On or Off
Off
Line input level
-40 dBm to 0 dBm
-13 dBm
Output power
5 watt to 50 watt
50 W
MARC port baud rate
300 to 9600 baud
9600
PTT input signal polarity
Positive or negative
Pos
PTT output signal polarity
Positive or negative
Pos
Inhibit input signal polarity
Positive or negative
Pos
BIT initiate input signal polarity
Positive or negative
Pos
Ready output signal polarity
Positive or negative
Pos
Operating frequency
118 to 136.975 MHz
118.000 MHz
Page 34
Store frequency channels
1 to 100
118.000 MHz
Page 35
Recall frequency channels
1 to 100
-
Page 36
Initiate a BIT test
-
-
Page 37
View BIT pages and advise screen
-
-
Page 38
Elapsed time indication
-
Page 39
Display
internal
reference
frequency screen
-
-
Page 40
Software versions
-
Page 41
T6T AM-Voice Operation