Digital Monitoring Products Inc PC0126P User Manual

Page of 10
9000 Series Installation Guide 
Digital Monitoring Products
7
Accessing Keypad Diagnostics
If necessary, refer to Access the Installer Menu earlier in this document.
Kpd Kpd  Kpd
Opt diag rF 
  StOp
  Keypad Diagnostics (KPD DIAG) 
The Keypad Diagnostic option allows you to check the display segments, keyboard backlighting 
and test individual keys.  
Press the Select key under KPD DIAG.  The keypad lights all display segments and illuminates 
the keyboard in Red.  In approximately one second the display backlighting changes to Green.  
The keypad alternates between these two states for approximately two minutes.  Press 
COMMAND at any time to begin testing individual keys.  
preSS Key tO
teSt
  Test Individual Keys
The display changes to PRESS KEY TO TEST.  This option tests each key on the keyboard to 
ensure it is operating properly.  Press and hold each key for about two seconds.  The key 
number being held appears in the display.  Verify the correct number displays before testing 
the next key. 
Accessing Keypad Wireless Survey
If necessary, refer to Access the Installer Menu earlier in this document.
Kpd Kpd  Kpd
Opt diag rF 
  StOp
  Keypad Wireless Survey Operation (KPD RF) 
The Keypad Survey option allows you to check the wireless communication between the 
keypad and the panel.  
Press the Select key under KPD RF.  The keypad logo blinks once to indicate proper operation.  
When the keypad does not receive an acknowledgement from the panel, the logo remains on 
for about 8 seconds to let you know communication is not established.  Communication is also 
faulty when the logo flashes multiple times in quick succession.  Relocate the keypad until 
the logo immediately turns off indicating the keypad and panel are communicating properly.  
Proper communication between the keypad and panel is verified when for each press of the 
Select key, the LED blinks immediately on and immediately off.  Repeat this test to confirm 
five separate consecutive LED blinks.  Any indication otherwise means proper communication 
has not been established. 
Exiting the Installer Options
When done, press the COMMAND key once to return to the Installer Options screen.  Press the Select key under STOP to 
exit the Installer Options function.