InstallatIon
Installation
4.1  Mounting the Enclosure
The metal enclosure must be mounted in a secure, dry place to protect the panel from damage due to 
tampering or the elements. It is not necessary to remove the PCB when installing the enclosure. The PCB 
may be installed in the standard 340 Small enclosure, optional 341 Kiosk enclosure, optional 349 Medium
enclosure, or the optional 349A Attack enclosure.
When using cellular communication or on-board wireless with the 341 enclosure, an SMA and wireless
antenna exit may be added at the time of the installation. The 349A Attack Resistant enclosure is factory
shipped with one knockout on the top left of the enclosure. As needed, additional knockouts may be
added at the time of installation. See Figure 3 for the positions on the enclosure that can be added. Each
additional knockout must be filled with conduit.
Dual 1/2" and 3/4" Conduit Knockout
Battery Shelf
Enclosure Mounting Holes
Slide panel PCB into lower enclosure slots 
Panel 
PCB 
screw
Model 349 Enclosure
Slide panel PCB between formed metal supports
Dual 1/2" and 3/4" Conduit Knockouts
Battery  Shelf
Enclosure  Mounting  Holes
Enclosure 
Mounting 
Hole
Enclosure 
Mounting 
Hole
Panel 
PCB 
screw
Model 340 Enclosure
J3
Phone 
Line
Outputs
J11
1 2 
3 4
J1
Ethernet
J16
Reset
J20
Wireless 
Antenna 
connection
J7 RJ 
Supervision
Panel 
PCB 
screw
Panel 
PCB 
screw
Enclosure 
Mounting 
Hole
J3
Phone 
Line
Outputs
J11
J1
Ethernet
J16
Reset
J20
Wireless 
Antenna 
connection
J7 RJ 
Supervision
1 2 
3 4
J18
Load
RED
Programming
J8
J18
Load
RED
Programming
J8
65555
263
Module
65555
263
Module
   
Figure 2: Standard 340 Enclosure (left), Optional 349 Enclosure (right) 
 
Figure 3: Optional 341 Enclosure (left), Optional 349A Enclosure (right) 
3-Hole 
Pattern for 
Accessory 
Modules
* 349A Optional Knockout
Front and 
Rear Tamper 
Switches for 
350A Attack 
Resistant 
Enclosure
Dual 1 3/4" and 1 3/8" Conduit Knockouts
Battery Shelf
*
*
*
*
*
Model 349A Enclosure
Slide panel PCB between formed metal supports
J3
Phone 
Line
Outputs
J11
J1
Ethernet
J16
Reset
J20
Wireless 
Antenna 
connection
J7 RJ 
Supervision
1 2 
3 4
J18
Load
RED
Programming
J8
65555
263
Module
Lid Mounting Holes (4 places)
Lid Mounting Holes 
   (4 places)
Enclosure Mounting Holes (4 places)
PEMs for optional battery bracket
Dual 1/2" and 3/4" Conduit Knockouts
J3
Phone Line
Outputs
J11
2
3
4
J1
Ethernet
J16
Reset
J20
Wireless 
Antenna 
connection 
(XT50 only)
J7 RJ 
Supervision
J18
Load
Programming
J8
OVC LED
Power 
LED
XMIT
TX  RX
Wireless LEDs
RCV
Tamper Mounting Holes
(Upper and Lower)
Openings drilled 
at installation
Model 341 Enclosure
65555
263
Module