XT30/XT50 Installation Guide 
Digital Monitoring Products
15
InstallatIon
Flash Load Jumper J18
16.1 Description 
The XT Series panel software can be updated via the panel’s programming (PROG) header. To update the
panel with a new software version, complete the following steps at the protected premise:
1. Place a jumper across the Reset (J16) header and then remove the yellow and green wires from keypad
bus terminals 8 and 9.
2. Connect a DMP 399 Cable from the J8 Programming Header to the serial port of your PC operating
Remote Link and containing the XT RU file. Requires Remote Link 1.43 or higher.
3. Start Remote Link and create or open the XT Series control panel account that matches the panel to be updated.
4. Set the Connection Information Type to Direct with a baud rate of 38400 and choose the appropriate COM port.
5. Select Panel>Remote Update, then select the correct RU file for the XT panel model.
6. While placing a short across the LOAD (J18) header, remove the jumper from the Reset (J16) header.
Click <Update> in Remote Link.
7. After the software version is updated, remove the short from the LOAD header. Place the jumper across
Reset (J16) then remove the 399 cable.
8. Replace the yellow and green wires to terminals 8 and 9.
9. Remove Reset (J16) jumper to resume normal panel operation.
Cellular Connections
17.1 Cellular 
The J24 header is provided to connect a 263G Digital Cellular Communicator, 263C CDMA Cellular
Communicator, or 263H HSPA+ Cellular Communicator. The cellular antenna connection protrudes through
the top of the enclosure.
Outputs
J11
4
J16
Reset
J20
1100 Series
Wireless Antenna 
connection
To J24 Celllular 
header
Connect 
antenna to 
right side 
only
Brass 
Washer
J18
Load
1100 Series
Antenna
(XT50)
J1
Ethernet
TX  RX
Wireless LEDs
Programming
J8
XMIT
RCV
65555
263 Module
 
              
Figure 9: Cellular and 1100 Series Wireless Antenna Connections