Digital Monitoring Products Inc PC0132 User Manual

Page of 22
 
9800 Series Keypad Installation Guide 
3
Internal Speaker Operation
All keypads emit standard tones for screen presses, entry delay, and system alerts. 
The speaker also provides distinct burglary, fire, zone monitor, and prewarn cadences. 
The keypads provide an alternate prewarn with alarm cadence that occurs when the 
status list displays a zone alarm.
Micro SD Card
The 9800 Series Wireless Graphic Touchscreen Keypads provide a spring-loaded Micro 
SD card slot on the right edge of the keypad housing. This is used to load a custom 
logo onto the main screen. Insert the Micro SD card straight in, with the contacts 
facing the wall, pressing in until a click occurs from the spring mechanism. To remove 
the Micro SD card, gently press in to allow the spring to eject the card. Grasp the 
edges of the card with two fingers and remove. See Figure 5.
Custom Dealer Logo
To display a custom dealer logo on the main screen, contact DMP Marketing at 
1-800-641-4282 or privatelabel@dmp.com for information. To add a custom dealer 
logo, see the Dealer Logo option under Installer Options menu.
AC Power/Armed LED Operation
The LED indicates the Power and Armed status of the panel. Depending on the 
operation, the LED displays in Red or Blue as listed in the table.
Internal Card Reader
When a proximity credential is presented to an internal or external reader, a beep 
tone is heard and the Power/Armed LED blinks. This provides both an audible and 
visual acknowledgement of the credential read. See Figure 6.
Figure 5: Micro SD Card Slot
Micro SD 
Card Slot
ARMED
TODAY
WEDNESDAY
Panic
Chime
Check-in
Reset
MON   5:35 AM
82
CURRENT
HI     LO
98   77
80
LO
74
HI
Color and Activity Operation
Blue Steady
Panel Disarmed, AC Power OK, Battery OK
Blue Blinking
Panel Disarmed, AC Power OK, Battery Fault
No Light
Panel Disarmed, AC Power Fault, Battery OK
Red Steady
Panel Armed, AC Power OK, Battery OK
Red/Blue Alternate
Panel Armed, AC Power OK, Battery Fault
Red Blinking
Panel Armed, AC Power Fault, Battery OK
Figure 6: Internal Card Reader Area
Internal Card Reader Area
ARMED
TODAY
WEDNESDAY
Panic
Chime
Check-in
Reset
MON   5:35 AM
82
CURRENT
HI     LO
98   77
80
LO
74
HI