Digital Monitoring Products Inc PC0181 User Manual

Page of 58
XTLplus Installation and Programming Guide 
Digital Monitoring Products
3
INSTALLATION
Installation
4.1  Mounting Location Information
A location should be selected that is centrally located between the 1100 Series transmitters used in the 
installation. Install the XTLplus away from metal objects. Mounting the panel on or near metal surfaces 
impairs performance. When selecting the proper mounting location of a transmitter, refer to the LED Survey 
Operation section of the specific installation guide for the transmitter being installed.
4.2  Mounting the Enclosure
The enclosure for the panel must be mounted using the provided #6 screws in the four mounting holes shown 
in Figure 1. Mount the enclosure in a secure, dry place away from metal objects to protect the panel from 
damage due to tampering or the elements. Mount the panel a minimum of 4 feet from any wireless 
transmitters or repeaters. It is not necessary to remove the PCB when installing the enclosure.
Figure 1: Mounting Hole Locations
Primary Power Supply
5.1  DC Input
Mount the panel near a wall outlet for the Model 372-500-W plug-in DC power supply. In addition to powering 
the panel, the DC plug-in power supply also charges the back-up battery. The 372-500-W must be located 
within 100 feet of the panel using 22 AWG wire. Use the following steps to connect the plug-in power supply:
OBSERVE POLARITY
1. Using 22 AWG wire, connect the panel DC terminal (+) to the positive terminal on the power supply.
2. Connect the panel DC terminal (-) to the negative terminal on the power supply. See Figure 2.
3. Plug the power supply into a 120 Volt AC, 60Hz dedicated outlet not controlled by a switch.
Figure 2: DC Power Supply Connection
Mounting Hole Locations
ZWave
Module
WiFi
Antenna
RESET
LOAD
B
AT
PROG
R       B
+ DC -
S
N
LEV
LPC-0181
     R1
INSTALL GUIDE
LT-1434
CELL
MODULE
©
  2015  DMP
WWW.DMP.COM
Wire Exits for DC 
Power Supply
+
Model 372-500-W
DC Plug-in
Power Supply
Use 22 AWG for 
Power Supply connection
_
RESET
LOAD
B
AT
PROG
R       B
+ DC -
S
N
LEV
LPC-0181
     R1
INSTALL GUIDE
LT-1434
CELL
MODULE
©
  2015  DMP
WWW.DMP.COM