PANEL SPECIFICATIONS
Panel Specifications
1.1  Power Supply
Model 372-500-W plug-in DC power supply
Input: 
 
 
120VAC, 60 Hz
Output: 
 
 
12VDC
Standby Battery: 
 
DMP 3.8VDC Lithium, 800mAh
Optional Standby Battery  
DMP 3.8VDC Lithium, 3500mAh
All circuits inherent power limited
1.2 Communication
Optional CDMA cellular module to send messages to DMP Model SCS-1R or SCS-VR Central Station Receivers.
Built-in Wi-Fi™ network alarm signal communication to DMP Model SCS-1R or SCS-VR Central  
Station Receivers.
1.3 Keypads
You can associate up to 4 alphanumeric 9000 Series or 9862 Graphic Touchscreen Wireless Keypads. 
1.4  Number of Zones
•  XTLplus has 48 wireless initiating zones numbered 1-48
•  Zone and Output numbers 51 to 54 and 61 to 64 can support 1144 Series Key Fobs, Output Modules,  
or sirens
1.5  Enclosure Specifications
The XTLplus panel ships in a plastic enclosure with a user’s guide and programming sheet.
Size
Color
5.5” W x 3.75” H x 1” D
White (W)
Introduction
2.1  System Configurations
The panel can be programmed to operate as any of the following system types:
•  All/Perimeter system that provides one perimeter area and one interior area
•  Home/Sleep/Away system that provides one perimeter, one interior, and one bedroom area. The bedroom 
area provides for any protection devices the user wants disarmed during their sleeping hours and armed in 
the Away mode.
•  Six area system that provides areas of protection that can be independently armed or disarmed.
2.2  Caution Notes
Throughout this guide you will see caution notes containing information you need to know when installing 
the panel. These cautions are indicated with a yield sign. Whenever you see a caution note, make sure you 
completely read and understand its information. Failing to follow the caution note can cause damage to the 
equipment or improper operation of one or more components in the system.
2.3  Compliance Instructions
For applications that must conform to a local authorities installation standard or a National Recognized 
Testing Laboratory certificated system, please see the Listed Compliance Specifications section near the end 
of this guide for additional instructions.