Digital Monitoring Products Inc PC0181 User Manual

Page of 58
Digital Monitoring Products
 
XTLplus Installation and Programming Guide
12
PROGRAMMING INTRODUCTION
19.8  Programming Menu
Accessing the Programmer
To access the programmer function of the XTLplus:
Use a standard LCD keypad, connect to the PROG header and set the keypad to Address 1.
Press the RESET button for two seconds.
Enter the code 6653 (PROG).
The keypad displays: PROGRAMMER.
Remove the hardwired keypad when programming is completed.
You are now ready to start programming the XTLplus panel. Pressing the COMMAND key scrolls you through 
the programming menu items listed below.
Menu Item
Section in This Manual
Menu Item
Section in This Manual
Initialization
20
Bell Options
29
Fast Program
21
Output Options
30
Communication
22
Output Setup
31
Network Options
23
 Area Information
32
Messaging Setup
24
Zone Information
33
Device Setup
25
Stop
34
Remote Options
26
Set Lockout Code
35
System Reports
27
Appendix
36
System Options
28
To select a section for programming, press any select key when the name of that section displays on the 
keypad. The detailed instructions for each programming step are found in sections 20 to 35 of this manual.
19.9  Programmer Lockout Codes
Although the XTLplus panel allows access to Programming without a lockout code, it is available to program 
one to restrict programming access to authorized individuals only. You can do this by using SET LOCKOUT 
CODE at the end of the programming menu.
Installing a lockout code
1. After entering the Programmer menu, the keypad displays PROGRAMMER. Press the COMMAND key until 
SET LOCKOUT CODE is displayed (after STOP).
2. Press any select key. At the ENTER CODE: - display, enter a 1- to 5-digit programmer lockout code.  
Press COMMAND.
3. The display shows ENTER AGAIN. Enter the same lockout code again and press COMMAND. The display 
shows CODE CHANGED. The new code number must now be entered before the Programmer menu can  
be accessed.
The lockout code should be written down and kept in a secure place with access limited to authorized 
persons only.
Lost Lockout Code requires factory reset: If you lose or forget the lockout code, the panel must be sent  
back to the factory to be reset. There is no field option for gaining access to the panel without a valid 
lockout code.
19.10 Reset  Timeout
The XTLplus has a feature that requires you to enter the Programmer within 30 minutes of resetting the 
panel. After 30 minutes, if you attempt to program by entering the 6653 (PROG) code, the keypad displays: 
RESET PANEL. You must reset the panel and enter the program code within the next 30 minutes.
If you are already in the Programmer and do not press any keys on the programming keypad for 30 minutes, 
the panel terminates programming. All data entered up to that point is saved in the panel’s memory.
To exit the panel’s Programmer you must use the Stop function. The STOP option is the second to the last 
option in programming. The programming session is then terminated and the keypad returns to the  
Status List.