Laird Controls North America Inc. 818A User Manual

Page of 45
Command Pro Engineered Systems 
User Manual 
16  
 
142134 
 
Figure 4: Antenna Clearance 
6.2.2  Receiver Location 
To ensure safe and reliable system operation, the following items must be considered when selecting a 
location for mounting the receiver: 
 
Install the receiver in an environment where the ambient temperature during operation does not drop 
below -20º F (-28º C) or rise above +160º F (+71º C).  
 
All connections to the receiver enclosure must be watertight.  
 
Avoid mounting the receiver enclosure on a surface where excessive vibration or shock is present. 
 
For easy access to wiring and for service, provide sufficient room to open the enclosure door. 
 
To ensure that the receiver enclosure is electrically at earth ground, remove all paint from the 
mounting-hole surfaces (refer to 
). 
 
Figure 5: Mounting-Hole Paint Removal 
 
Mount the receiver enclosure securely using appropriate locking-type hardware. This also assists in 
properly grounding the receiver enclosure to the mounting surface.