UTC Fire & Security Americas Corporation Inc 569E-LMRISE User Manual

Page of 3
Learn Mode Rate of Rise Heat Sensors Installation Instructions  
Figure 3. Mounting holes 
 
Replacing the batteries 
When the sensor battery gets low, the sensor transmits a low 
battery signal. The panel receives this signal and sounds 
trouble beeps through the system sirens. Pressing the Status 
button identifies the sensor with the low battery. 
Replace the battery immediately when this condition occurs, 
using the following batteries: Eveready
©
 9-Volt Alkaline 
Energizer (No. 522); Duracell
©
 9-Volt Alkaline (MN1604); or 
UltraLife
©
 9-Volt Lithium. 
Battery disposal 
Alkaline and lithium batteries that are not longer usable are 
considered hazardous waste. Be sure to properly dispose of 
the old batteries according to your local hazardous waste 
disposal laws. 
Specifications 
Compatibility 
Interlogix/GE Learn Mode panels and 
receivers 
Frequency 
319.5 MHz 
Power requirements 
One 9-volt alkaline or lithium battery 
Operating temperature  60-460-95/NX495, 60-460-95-LB: 
40 to 100°F (4 to 37°C) 
60-460-01-95/NX-496:  
32 to 150°F (0 to 66°C) 
Storage temperature 
60-460-95/NX-495, 60-460-95-LB: 
-30 to 120°F (-34 to 48°C) 
60-460-01-95/NX-496: 
-30 to 140°F (-34 to 60°C) 
Maximum humidity 
90% relative humidity, noncondensing 
Dimensions 
4.4 in. (11.18 cm) diameter x 2.2 in. (5.59 cm) 
depth 
Regulatory information 
Manufacturer 
UTC Fire & Security Americas Corporation, Inc. 
1275 Red Fox Rd., Arden Hills, MN 55112-6943, 
USA 
UL listings 
UL 985 Household Fire Warning System Units 
UL 521 Heat Detectors for Fire Protective 
Signaling Systems 
 
This equipment has been tested and found to comply with the limits for a 
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are 
designed to provide reasonable protection against harmful interference in a 
residential installation.  
This equipment generates, uses and can radiate radio frequency energy and, 
if not installed and used in accordance with the instructions, may cause 
harmful interference to radio communications. However, there is no 
guarantee that interference will not occur in a particular installation.  
If this equipment does cause harmful interference to radio or television 
reception, which can be determined by turning the equipment off and on, the 
user is encouraged to try to correct the interference by one or more of the 
following measures:  
• 
Reorient or relocate the receiving antenna.  
• 
Increase the separation between the equipment and receiver.  
• 
Connect the equipment into an outlet on a circuit different from that to 
which the receiver is connected.  
• 
Consult the dealer or an experienced radio/TV technician for help.  
Changes or modifications not expressly approved by UTC Fire and Security 
could void the user’s authority to operate the equipment. 
This device complies with Industry Canada licence-exempt RSS standard(s). 
Operation is subject to the following two conditions: (1) this device may not 
cause interference,and (2) this device must accept any interference, 
including interference that may cause undesired operation of the device. 
Cet appareil est conforme avec Industrie Canada exempts de licence 
standard RSS (s). Son fonctionnement est soumis aux deux conditions 
suivantes: (1) cet appareil ne doit pas provoquer d'interférences et (2) cet 
appareil doit accepter toute interférence, y compris celles pouvant causer un 
mauvais fonctionnement de l'appareil. 
In accordance with FCC requirements of human exposure to radiofrequency 
fields, the radiating element shall be installed such that a minimum 
separation distance of 20 cm is maintained from the general population. 
FCC: B4Z-569E-LMRISE
 
IC: 1175C-569EROR
 
This Class B digital apparatus complies with Canadian ICES-003. 
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du 
Canada. 
Contact information 
For contact information, see www.utcfireandsecurity.com or 
www.interlogix.com. 
For technical support, toll-free: 888.437.3287 in the US 
including Alaska, Hawaii, Puerto Rico, and Canada. Outside 
the tool-free area, contact your dealer. 
GE is a trademark of the General Electric Company and is 
under license to UTC Fire & Security, 9 Farm Springs Road, 
Farmington, CT 06034-4065 
Copyright © 2011 Interlogix, a UTC Fire & Security Company. 
All rights reserved.