Timers (1st Tier)
Options (1st Tier)
Entry Dly
 (Timers)
2nd Tier
(Default = 30 seconds, Parameters = 30-240 seconds) Entry 
Delay determines how much time the user has to disarm the 
system after entering the armed premises through a 
“designated delay door,” (grp 10) without causing an alarm.
Note 
For UL Listed installations, the Entry Delay must be set to 
45 seconds or less.
To set the entry delay:
‰ Press #, enter desired time and then press #. 
Exit Dly
 (Timers)
2nd Tier
(Default = 60 seconds, Parameters = 45-254 seconds) Exit 
Delay determines how much time the user has after arming the 
system to leave the premises through a “designated delay 
door,” (group 10 or 19) without causing an alarm.
Note 
For UL Listed installations, the Exit Dly must be set to 60 
seconds or less.
To set the exit delay:
‰ Press #, enter desired time and then press #.
Phone Test Frequency
 (Timers)
2nd Tier
(Default = 7 days, Parameters = 1-255 days) Phone Test 
Frequency determines how often the panel conducts the 
automatic phone test. The system can be set to perform an 
automatic phone test anywhere from every day to every 255 
days. To turn this option off, turn off Auto Phone Test under 
the Reports option.
Note 
For UL Listed installations, the Next Phone Test and Phone 
Test Frequency must be set to 1.
To set the phone test frequency:
‰ Press #, enter desired number of days and then press #. 
Next Phone Test 
 (Timers)
2nd Tier
(Default = 7 days, Parameters = 1-255 days) Next Phone Test 
is used by the Auto Phone Test feature to determine when the 
next automatic phone test should occur. This setting should be 
the same as, or less than, the Phone Test Frequency setting. To 
turn this option off, turn off Auto Phone Test under the Reports 
option.
To set the next phone test:
‰ Press #, enter desired time (1-255 days) and press #. 
Sleepy Time
 (Timers)
2nd Tier
(Default = on) Sleepy Time determines whether sleep hour is 
enabled or disabled. If enabled, proceed to Sleep Hour to set 
the sleep time desired.
Important !
Fire related trouble beeps are not affected by Sleepy Time.
Note 
For UL Listed installations the Sleepy Time option must be 
set to off.
To set the sleepy time:
‰ Press # to turn on or off. 
Sleep Hour
 (Timers)
2nd Tier
(Default = 22, Parameters = 0-23) Sleep Hour determines the 
start time of a 10 hour window during which trouble beeps are 
suppressed. For example, if sleep time is set to 22 (10 p.m.) 
then non-fire related trouble beeps will not start between 10 
p.m. and 8 a.m.
To set the sleep hour:
‰ Enter desired time (00-23) and then press #
KTP Arm
(Options)
2nd Tier
(Default = off) When Keychain Touchpad Arm is on, pressing 
the lock button on keychain touchpads arms the system 
directly with NO DELAY. 
When this setting is off, each key-press increments the arming 
level without NO DELAY.
To turn keychain touchpad arm on or off:
‰ Press # to turn on or off. 
Police Panic 
 (Options)
2nd Tier
(Default = on) This setting determines whether panel keypad 
police panic buttons are enabled (on) or disabled (off). If 
enabled, an immediate Police alarm will occur after the police 
panic buttons are pressed for two seconds and the panel 
displays the alarm as a police panic. If the DTIM is installed 
with the system; 
An alarm report will be issued.
If the dialer delay option is on, the report will be delayed 
or can be aborted.
To turn the police panic on or off:
‰ Press # to turn on or off.