Emergency Panic 
 (Options)
2nd Tier
(Default = off) This setting determines whether panel keypad 
emergency panic buttons are enabled (on) or disabled (off). If 
enabled, an immediate alarm will occur after the emergency 
panic buttons are pressed for two seconds and the panel 
displays the alarm as an emergency panic. If the DTIM is 
installed with the system; 
An alarm report will be issued.
If the dialer delay option is on, the report will be delayed 
or can be aborted.
To turn the emergency panic on or off:
‰ Press # to turn on or off. 
Fire Panic 
 (Options)
2nd Tier
(Default = on) This setting determines whether panel keypad 
fire panic buttons are enabled (on) or disabled (off). If enabled, 
an immediate Fire alarm will occur after the fire panic buttons 
are pressed for two seconds and the panel displays the alarm as 
a fire panic. If the DTIM is installed with the system, an 
immediate alarm report will be issued. 
Note 
The alarm report cannot be aborted or cancelled.
To turn the fire panic on or off:
‰ Press # to turn on or off. 
Rcvr Trouble
 (Options)
2nd Tier
(Default = off) When Receiver Trouble is on, the panel reports 
a receiver failure under the following conditions: 
A wireless sensor signal has not been received for two 
hours or 
The receiver is being jammed with a constant signal.
Note 
For UL Listed installations using wireless devices, Receiver 
Trouble must be set to on.
To turn receiver trouble reports on or off:
‰ Press # to turn on or off. 
Panel Tamper
 (Options)
2nd Tier
(Default = on) Panel Tamper determines how the panel handles 
possible tamper situations. When this feature is on, the panel 
reports a panel tamper if the panel back cover or DTIM cover 
is opened while the panel is armed. A police alarm will sound 
and 
PANEL
 
TAMPER
 will be displayed. If this feature is off, the 
panel will display a status message only.
To turn the panel tamper on or off:
‰ Press # to turn on or off. 
Exit Ext
 (Options)
2nd Tier
(Default = on) When Exit Extension is on, the panel restarts 
the exit delay timer if the user re-enters the premises through a 
standard delay door before the standard exit delay time 
expires.
This helps prevent exit faults and false alarms by allowing 
users to re-enter the premises for a forgotten item.
When this feature is off, the exit delay timer does not restart if 
the user re-enters the premises, forcing the user to disarm the 
system to avoid setting off an accidental alarm.
Note 
For UL Listed Installations the Exit Extension option must 
be set to off.
To turn exit extension on or off:
‰ Press # to turn on or off. 
Swinger Shutdown
 (Options)
2nd Tier
(Default = 1, Parameters = 1-2) This setting determines the 
maximum number of times a sensor or zone can go into alarm 
(during a single arming period) before the panel automatically 
bypasses that sensor or zone. This feature only applies to 
sensors or zones in groups 0, 1, 4, 6, 8-10, and 13-23.
When set to 1, the panel automatically bypasses a sensor or 
zone after it causes an alarm. When set to 2, the panel waits 
until a sensor or zone has caused a second alarm (during the 
same arming period) before bypassing it. At any setting, the 
automatic bypass is logged into the event buffer and can only 
be viewed thru ToolBox.
The bypassed sensor or zone will be cleared (automatically 
unbypassed) if the system receives no further activations from 
that sensor or zone over the next 48–50 hours.
Changing the arming level also clears all bypassed sensors and 
zones and resets the Swinger Limit count on all sensors and 
zones.
To set the swinger shutdown:
‰ Press #, enter desired number and then press #. 
Quick Arm
 (Options)
2nd Tier
(Default = off) Quick Arm allows system arming without 
using an access code. When Quick Arm is on, the system 
arming level can be increased without entering an access code.
A valid access code is still required to disarm the system.
To turn quick arm on or off:
‰ Press # to turn on or off.