About This Manual
This manual provides information for planning, installing, 
programming, and testing this security system. When nec-
essary, this manual refers you to other documentation 
included with compatible devices.
Planning sheets are included for you to record hardware 
layout and software programming settings.
Special Installation Requirements
This security system can be used as an intrusion alarm sys-
tem, a fire alarm system, and an emergency notification 
system.
Some installations may require configurations dictated by 
city/state codes, insurance, or Underwriter’s Laboratories 
(UL). This section describes the various component and 
configuration listings.
UL Listed Systems
This section describes the requirements for UL Listed 
systems.
Basic System
‰ Control Panel (60-874-95R).
‰ Standard Class II 8.0 VAC, 300 mA Power Trans-
former; manufacturer—Sino America, (A1014444-0) 
ITI Part No. 22-117.
‰ Dialog Telephone Interface Module (DTIM) 
(60-879-95R).
‰ Backup Battery 4.8 VDC rechargable NiCd battery 
pack (34-057).
Household Burglary Alarm System Unit (UL 1023)
Basic system, plus:
‰ Hardwire Magnetic Contact (13-068 or 13-071) or 
Wireless Learn Mode Door/Window Sensor (60-362), 
Wireless Learn Mode PIR Motion Sensor (60-703-95 
or 60-639).
‰ RECEIVER TROUBLE set to on.
‰ EXIT DELAY set to 60 seconds or less.
‰ QUICK EXIT set to off.
‰ SIREN TIMEOUT set to 4 minutes or more.
‰ ENTRY DELAY set to 45 seconds or less.
‰ SLEEPY TIME set to off.
Household Fire Warning System (UL 985)
Basic system, plus:
‰ Wireless Smoke Sensor (60-506-319.5 or 60-848-95) 
learned into sensor group 26.
‰ RECEIVER TROUBLE set to on.
‰ SLEEPY TIME set to off.
‰ EXIT EXTENSION set to off.
Digital Alarm Communicator System (UL 1635)
Basic system, plus:
‰ AC FAILURE set to on.
‰ LOW CPU BATTERY set to on.
‰ AUTO PHONE TEST set to on.
‰ PHONE TEST FREQUENCY set to one.
‰ NEXT PHONE TEST set to one.
Central Station Reporting
The panel has been tested with the following central station 
receivers using SIA and Contact ID reporting formats:
‰ ITI CS-5000 Central Station Receiver.
‰ Sur-Gard Central Station Receiver with models 
SG-DRL2A and SG-CPM2.
UL-Canada Listed Systems
This section describes the requirements for ULC (UL 
Canada) Listed systems.
CSA Certified Accessories
Residential Burglary Alarm System Unit (ULC-S309)
Same as “UL Basic System and Household Burglary Alarm 
System Unit (UL 1023).”
California State Fire Marshall Listed 
Systems
Same as Household Fire Warning System (UL 985).
Planning the Installation
This section describes the systems’s capabilities to help you 
get familiar with the system. Appendix B provides planning 
sheets with tables that let you record the hardware and pro-
gramming configuration of the system to help prepare for 
system installation.
Standard System
Panel
The panel keypad provides complete system programming 
and operation control. Displays system messages and indi-
cates system status.
DTIM
The DTIM allows the panel to communicate with the cen-
tral monitoring station.
Note
The DTIM does not have a backup battery.
The following describes the system’s basic (out-of-box) 
hardware capabilities.
‰ Power: AC Class II, 8 VAC transformer.
‰ Backup Battery 4.8 VDC rechargable NiCd battery 
pack. (34-057)
‰ One Supervised Hardwire Zone: Input for various hard-