3
Allegro
Preliminary 2/5/02
wired detectors.
‰ Built-In Radio Receiver: Allows use of up to 20 ITI 
319.5 MHz. crystal and/or SAW Learn Mode wireless 
sensors and touchpads.
‰ Built-In Siren: Capable of 85 dBa @ 3m.
‰ Built-In Panel Keypad.
‰ Liquid Crystal Display (LCD).
Additional System Components
The system can monitor up to 20 sensors using any combi-
nation of the following sensors:
‰ Door/Window Sensor (60-670-95R).
‰ 2-Button Keychain Touchpad (60-607-319.5).
‰ Remote Handheld Touchpad (60-671-95R).
‰ Indoor Motion Sensor (60-639-95R).
‰ Carbon Monoxide Alarm (60-652-95)
*
.
‰ Smoke Sensor (60-747-95).
‰ ShatterPro Glass Break (60-873-95)*.
‰ Other supported ITI 319.5 Sensors (excluding other 
touchpads).
Note
Both ITI SAW and Crystal sensors function with this control 
panel.
Installing the System
Before starting the installation, plan your system layout 
and programming using the worksheets provided in Appen-
dix B.
Installing the system consists of the following:
‰ Determining the Panel Location.
‰ Mounting the Panel.
‰ Identifying Main Panel Components.
‰ Connecting Detection Devices to Panel Zone Input.
‰ Installing an RJ-31X Phone Jack for the DTIM.
‰ Connecting the AC Power Transformer.
‰ Powering Up the Panel.
Determine the Panel Location
Before permanently mounting the panel, determine panel 
location using the following guidelines:
‰ Avoid running wires parallel with electrical wiring or 
fixtures such as fluorescent lighting, to prevent wire 
runs from picking up electrical noise.
‰ Mount the panel at a comfortable working height 
(about 45 to 55 inches from the floor to the bottom of 
the panel).
‰ Leave space above the panel for optional antenna plas-
tic (min 4 inches).
Important !
The panel must be mounted at least 10 feet from any DTIM 
or between any two DTIMs.
Mounting the Panel
Use the following procedure to mount the panel to the wall 
or wall studs.
CAUTION
Make sure you are free of static electricity whenever you 
work on the panel with the back mounting plate removed. 
Using an approved grounding strap is recommended.
To mount the panel:
1.
Remove the panel from the back 
mounting plate by lifting the tab 
located on the top and pulling 
back.
Figure 1. Remove back 
by lifting tab
2.
Remove the wiring knockout.
Figure 2. Back Mounting Plate
3.
Feed all device wires through the knockout and place 
the back mounting plate in position against the wall.
4.
Level the back mounting plate and mark the top and 
bottom mounting holes.
5.
Install anchors where studs are not present.
6.
Partially insert a screw into the top mounting hole loca-
tion then hang the back mounting plate on the screw.
7.
Recheck for level, insert the lower screw, and tighten 
both mounting screws.
8.
Install the antenna. There are three antenna options to 
choose from:
*) Not investigated by UL.
Tab
Antenna
(Option 3)
Antenna
Wire Hole
(Option 2)
Wire
Clip
Mounting
Holes
Knockout
Tamper