UTC Fire & Security Americas Corporation Inc 799E5-SOUND User Manual

Page of 6
© DDMONYY UTC Fire & Security. All rights reserved. 
1 / 6 
P/N 466-5401 
• REV B • 9MAY18 
 
ShatterPro
®
 Glassbreak Sensor 
Installation Sheet 
Product Summary 
The ShatterPro
®
 omnidirectional glassbreak sensor (60-873-
95) provides 360 degree coverage. It can be mounted on the 
ceiling, or on the opposite wall, or on adjoining walls. It has a 
range of up to 20 feet for glass panes 1' x 2' (0.3 m x 0.6 m) 
or larger. 
Figure 1: 
ShatterPro Glassbreak Sensor 
 
 
The maximum detection range is 20' (6 m) for plate, 
tempered, laminated and wired glass. For armor-coated 
glass, the maximum detection range is 12' (3.65 m). 
Coverage is measured from the sensor to the point on the 
glass farthest from the sensor (see D and D' in Figure 2 
below). See Specifications on page 4 for recommended 
glass thickness. 
Figure 2: 
Optimum Performance Zone 
 
Note:  ShatterPro may not consistently detect cracks in 
glass, or bullets that break through the glass. 
Glassbreak sensors should always be backed up by 
interior protection. 
Installation Guidelines 
For best detection, avoid installing in rooms with lined, 
insulating, or sound deadening drapes or rooms with closed 
wooden window shutters inside. 
 
Do not use sensor near air compressors. A blast of 
compressed air may cause a false alarm. 
 
Avoid stairwells, glass booths, and all rooms smaller 
than 10' x 10' (3 m x 3 m). 
 
The Pattern Recognition Technology™ of the 
ShatterPro ignores most false alarm sounds. Some 
sounds can duplicate the glass break pattern the 
ShatterPro detects, however, so the ShatterPro works 
best in rooms with only moderate noise. Avoid rooms 
where white noise, such as a fan, is present. Avoid 
rooms with noisy areas or multiple noise sources such 
as small kitchens or bathrooms, garages, etc. 
Note:  For glass break protection in these applications 
(where ShatterPro is not appropriate), use shock 
sensors on the windows or window frames. 
 
Avoid adding (learning) the sensor into 24-hour sensor 
groups, where the sensor will be armed even when the 
room is in use. Like a motion detector, a glass break 
sensor may be tripped when occupants are in the 
protected area. Adding the ShatterPro to a perimeter 
sensor group, which is armed only when the perimeter 
doors and windows are armed, will help prevent false 
alarms. 
 
The device may not work properly in humid rooms. Do 
not install it in such conditions. 
Tools needed 
 
Phillips screwdriver 
 
A 5709C-W hand-held tester 
 
Note: Please see page 6 for important product safety, 
warranty, limitation of liability, and disclaimer 