UTC Fire & Security Americas Corporation Inc 799E5-SOUND User Manual

Page of 6
P/N 466-5401 
• REV B • 9MAY18 
 
3 / 6 
2.  Hold the tester speaker directly on top of the sensor and 
activate the tester. The sensor will alarm; then it will go 
into test mode for one minute. While in the test mode, 
the LED on the sensor will blink continuously. 
Extend the test mode time by activating the tester at 
least once a minute. 
3.  Holding the tester near the surface of the glass and 
behind any closed drapes or blinds, aim the tester at the 
ShatterPro and hold down the test button (see Figure 5: 
Testing the ShatterPro on page 2). 
Remember, the ShatterPro should not be installed in 
rooms with lined, insulating, or sound deadening drapes 
or rooms with closed wooden window shutters inside. 
4.  Observe the LED on the sensor. If the sensor is 
detecting the tester signal, the LED will remain on but 
will stop blinking momentarily. This indicates the sensor 
is mounted within range and is working properly. 
If the sensor LED blinks continuously when the test 
button is pressed, the sensor is not detecting the tester 
signal. Replace the tester battery if you suspect it is not 
producing a strong signal. If you are certain that the 
tester signal is strong, reposition the sensor closer to 
the window and retest. Add more sensors if necessary 
to achieve complete coverage. 
5.  The sensor will automatically exit test mode if it does not 
sense any signals for 1 minute. 
The “Hand Clap” Test 
You can test the ShatterPro without enabling the test mode 
by clapping your hands loudly under the sensor. This sound 
will not trip the alarm, but the sensor LED will blink twice. 
This is a signal that the sensor has power and that the 
microphone and circuit board are functioning. 
Adding the ShatterPro to Panel Memory 
The following procedure is a general guideline for adding 
(learning) the sensor into panel memory. Refer to your panel 
installation instructions or reference manual for complete 
details. 
1.  Set the panel to Program mode. 
2.  Proceed to the LEARN SENSORS menu. 
3.  Select the appropriate sensor group and sensor 
number. 
4.  Trip the tamper switch on the sensor. 
5.  Repeat the above steps until all sensors are added 
(learned) into the panel. 
6.  Exit Program mode. 
Testing the System 
The following steps describe general guidelines for testing 
the sensor. Refer to your panel installation instructions or 
reference manual for complete details. 
1.  Set the panel to the Dealer Sensor Test mode. 
2.  Use the hand-held tester to trip the sensor. 
3.  Listen for status beeps (or a voice message) to indicate 
that the panel is receiving transmissions from the sensor 
OR 
Look for a message on the touchpad display. 
Note:  Refer to your panel installation instructions for 
troubleshooting information.