Do not mount the sensor near duct work or other large metallic surfaces which may affect the 
RF signals (see “Final Testing” on page 4). Actual acceptable transmitter range should be ver-
ified for each installation.
Windows should be closed in any area which has an armed motion sensor.
Note 
The cardboard undercrawl 
mask should remain 
installed when sensor 
jumper J1 is set to the BI 
position. See the section 
“Setting the Sensor Cover-
age Area and Sensitivity” for 
complete information on 
sensor jumper settings.
The cardboard undercrawl mask installed at the factory (see Figure 2) blocks coverage within 
5 feet of the sensor.
For installations where pets are present, mount the sensor upside down about 3.5 feet above 
the floor (see Figure 3). Leave the factory-installed undercrawl mask in place to block any 
detection pattern directed at the ceiling
Tools and Supplies Needed
Phillips screwdriver
Anchors and screws for mounting (included)
Masks (included)
Mounting the 
Motion Sensor
This section describes how to mount the sensor on a flat wall or in a corner.
You must be free of static electricity before handling circuit boards. Wear a 
grounding strap or touch a bare metal surface to discharge static electricity.
Static
Note 
Remove the factory-installed 
plastic masks before mount-
ing. Re-install as desired 
after walk testing.
1. Remove the small cover (see Figure 4)
2. Open the sensor housing by pressing down on the top rear and pulling the front cover at the 
top (see Figure 5). Set the front cover aside
Figure 2. Cardboard Undercrawl 
Figure 3. Pet Alley Application
Mask Location
S T E P   1 :
P R E S S   D O W N
W I T H   I N D E X   F I N G E R
S T E P   2 :
P U L L   A W A Y
Figure 4. Removing the Small Cover
Figure 5. Opening the Sensor Housing