UTC Fire & Security Americas Corporation Inc 844-PIR User Manual

Page of 8
3
Sentrol AP750W Wireless PIR Motion Sensor Installation Instructions
Preliminary 9/1/04
Note 
Avoid touching the 
mirror. Fingerprints may 
affect detection coverage.
3.
Mount the sensor on a flat wall or in a corner, using the appropriate mounting holes (see Fig-
ure 6). Use wall anchors and screws to secure the sensor.
Figure 6. Mounting Hole Locations
Setting the 
Sensor 
Coverage Area 
and Sensitivity
Jumper J1 determines the sensitivity mode of the sensor, either standard or bi-curtain. Jumper J2 
determines the coverage area of the sensor, either 33 or 50 feet. See Figure 7 for jumper positions.
Use the standard (STD) setting for wide-angle coverage and single curtain pattern. Use the bi-cur-
tain (BI) setting for added stability to help reduce false alarms. This mode requires intruders to be 
detected by two curtains of coverage.
Note 
Do not use the bi-curtain 
mode for detection in areas 
within 5 feet of the sensor. 
When selecting bi-curtain 
mode, always leave the 
cardboard undercrawl mask 
installed.
You must be free of static electricity before handling circuit boards. Wear a 
grounding strap or touch a bare metal surface to discharge static electricity.
Static
Figure 7. Sensitivity Mode and Coverage Area Jumper Settings
Walk Testing
Walk testing should be done to determine the actual coverage area of the sensor. The edge of the 
coverage pattern is determined by the first LED flash. This may change slightly depending on the 
sensitivity setting. Walk test the unit from both directions to determine the pattern boundaries.
1. Remove the sensor cover to activate the tamper switch, then reattach it to activate the 2-
minute walk test mode.
2. Walk across the coverage pattern to determine the coverage area, indicated by LED activation.
After 2 minutes, the walk test mode and the LED will no longer activate when motion is detected.
Note  
Excessive use of the walk test mode may reduce battery life. Use only for initial setup and maintenance 
testing. In normal operation mode, the sensor only transmits an alarm signal 135 seconds after the pre-
vious alarm. This reduces unnecessary RF transmissions in high traffic areas, thereby extending battery 
life.
C O R N E R
M O U N T I N G
H O L E S
( 4 )
F L A T
M O U N T I N G
H O L E S
( 2 )
M I R R O R
M I R R O R
J 1 J 2
J 1
J 2
J 1 - S E N S I T I V I T Y   M O D E
B I   =   J U M P E R   O N   T O P   T W O   P I N S
S T D   =   J U M P E R   O N   L O W E R   T W O   P I N S
J 2 - C O V E R A G E   A R E A
5 0   F T   =   J U M P E R   O N   T O P   T W O   P I N S
3 3   F T   =   J U M P E R   O N   L O W E R   T W O   P I N S