Sentrol AP750W Wireless PIR Motion Sensor Installation Instructions
Preliminary 9/1/04
Programming
The following describes the basic steps for adding (learning) the sensor into panel memory. Refer 
to the specific panel installation instructions for complete programming information.
1. Put the panel into program mode.
2. Advance to the learn sensors menu.
3. Enter the appropriate sensor group and desired sensor number.
4. When the panel prompts you to trip the sensor, activate the sensor tamper switch by removing 
the sensor cover.
5. Reattach the sensor cover.
6. Exit from program mode.
Final Testing
Final testing should be done to verify radio signal integrity and confirm control panel program-
ming and response. The actual transmitter range can be determined by performing a sensor test as 
described below. Refer to the specific panel installation instructions for complete sensor testing 
information.
1. After the sensor has been mounted, remove the sensor cover to trip the tamper switch and acti-
vate the walk test mode.
2. Replace the sensor cover.
3. Place the control panel in test mode.
4. Move across the detection pattern until the sensor LED turns on, then STOP your motion.
5. Listen for the appropriate system response. If the system does not respond, proceed to the 
“Troubleshooting” section.
Maintenance
At least once a year, the sensor should be tested to verify correct operation. The end user should 
be instructed to put the sensor in walk test mode and walk through the far end of the coverage pat-
tern to verify proper detection.
Replacing Batteries
When battery replacement is necessary, observe proper polarity (positive +, negative -) when 
installing the new batteries, or the sensor may be damaged.
Use only exact replacement 3-volt lithium batteries (CR123A).
You must be free of static electricity before handling circuit boards. Wear a 
grounding strap or touch a bare metal surface to discharge static electricity.
Static
1. Remove the sensor cover (see Figures 4 and 5) and set it aside.
2. Remove the transmitter (upper) circuit board battery (see Figure 10)
3. Remove the transmitter circuit board and place it inside the cover (see Figure 11)
T R A N S M I T T E R
B O A R D
P U L L   O U T   O N
E I T H E R   T A B
W H I L E   P U L L I N G
T R A N S M I T T E R
B O A R D   U P .
Figure 10. Removing the Transmitter Battery
Figure 11. Removing the Transmitter Circuit Board