UTC Fire & Security Americas Corporation Inc 875-TCVR User Manual

Page of 4
2
SuperBus 2000 319.5 MHZ RF Transceiver Module Installation Instructions
Preliminary 8/5/04
Installation
Installation Guidelines
Observe the following guidelines when installing the transceiver module:
Concord
 systems can accommodate a maximum of 96 wireless sensors/zones.
In Concord systems, up to 16 SuperBus 2000 devices can be connected to the panel 
(SuperBus 2000 Touchpads, Receivers, Transceivers, HIMs, HOMs, ESMs, etc.). 
Each bus device must have a different unit number.
Leave 4 inches above the module for the antenna.
When mounting the module away from the panel, use the wire length guidelines in 
Table 2.
Avoid areas that are likely to expose the module to moisture.
Avoid areas with excessive metal or electrical wiring, including furnace and utility 
rooms. If unavoidable, mount on or near metal with the antenna extending above the 
metallic surfaces, as shown in Figure 2.
Figure 2. Mounting on or Near Metal
Tools and Supplies
Screwdrivers
Drill with bits
Mounting screws and anchors (included)
4-conductor, 22-gauge or larger, stranded wire
Support standoff (included with Concord cabinet)
¼-inch press-fit reed switch and magnet (not included)
Small hammer
Mounting the Transceiver
The module can be mounted on any interior wall (protected from the elements).
SuperBus 2000 Device ID Number Label
Identifies unique module SuperBus 2000 
device ID number (SuperBus 2000 panels).
Transceiver Status LED
On continuously when the transceiver is 
powered. Flashes when an RF signal is 
received.
Terminal Strip
Used for power and bus connections to panel.
Table 1: Component Descriptions
Component
Function
Table 2: Maximum Module Wire Lengths
Wire Gauge (Unshielded or 
Shielded)
Max. Wire Length Between Module and Concord 
Panel
18
2,800 feet
22
1,100 feet
METAL
METAL