External contact wiring
Use the following specifications for the external contact:
• Maximum wire length: 26 ft. (8 m).
• Wire: Stranded, 22-gauge (0.7112 mm).
• Switches: Hermetically sealed external switches (sealed
• Wire: Stranded, 22-gauge (0.7112 mm).
• Switches: Hermetically sealed external switches (sealed
reed switches) that supply a minimum 250 ms open or close
on alarm.
on alarm.
Note: Do not connect more than five external contacts to a door/
window sensor.
You can wire the sensor terminal blocks with leads from an
external contact (Figure 8). The door/window sensor provides
alarm and tamper indication. Wire the external contact with one
end-of-line (EOL) resistor in series with the external contact.
external contact (Figure 8). The door/window sensor provides
alarm and tamper indication. Wire the external contact with one
end-of-line (EOL) resistor in series with the external contact.
This gives the following readings for each configuration:
Figure 8 shows external contact wiring (normally closed and
normally open).
normally open).
Figure 8. External contact wiring
Sensor test
The sensor test verifies proper communication between the
sensor and the panel/receiver. To test the sensor, refer to the
specific panel/receiver documentation and do the following:
1.
sensor and the panel/receiver. To test the sensor, refer to the
specific panel/receiver documentation and do the following:
1.
Put the panel/receiver into sensor test mode.
2.
Open the door/window the sensor is protecting. The sensor
transmits a signal.
transmits a signal.
3.
Listen for siren beeps to determine the appropriate response.
4.
Exit sensor test mode.
Battery replacement
When the system indicates low sensor battery, replace it immedi-
ately. Use the recommended replacement batteries (see
ately. Use the recommended replacement batteries (see
).
To replace the batteries:
1.
1.
Remove the sensor cover.
2.
Remove the battery. Follow local laws for battery disposal.
3.
Insert the replacement battery, observing correct polarity
(Figure 3 on page 1).
(Figure 3 on page 1).
4.
Perform a sensor test with the panel. See
.
Specifications
CAUTION: You must install the EOL resistor at the
external detection device for proper supervision.
Normally closed
Zero ohm/short = Tamper
4.7 Kohm = Normal
Open = Alarm
Zero ohm/short = Tamper
4.7 Kohm = Normal
Open = Alarm
Normally open
Zero ohm/short = Tamper
4.7 Kohm = Alarm
Open = Normal
Zero ohm/short = Tamper
4.7 Kohm = Alarm
Open = Normal
Door/Window
Contacts
EOL resistor
Sensor
4.7 Kohm
Model number
Brown: 60-362N-11-319.5
White: 60-362N-10-319.5
White: 60-362N-10-319.5
Frequency
319.5 MHz
Compatibility
GE Security 319.5 MHz control panels/
receivers
Battery type
3.0 V, 1300 mAh lithium
Required batteries
Duracell DL 123A, Panasonic CR123A, Sanyo
CR123A, Varta CR123A
Estimated battery life
5 to 10 years at 20°C (68°F) depending on the
number of activations per day
Magnet gap
3/8 in. (max.)
Supervisory interval
64 minutes
End-of-line resistor
4.7 Kohm
Typical RF output power
0.25mW EIRP
Operating temperature
10 to 120°F (-12 to 49°C)
Storage temperature
-30 to 140°F (-34 to 60°C)
Relative humidity
0 to 90% noncondensing
Dimensions (L x W x D)
3.02 x 1.5 x 1.02in. (81 x 38 x 26 mm)
Weight
44 g
Listings
UL 1023, UL 1610
FCC
This device complies with part 15 of the FCC rules. Operation is
subject to the following conditions:
This device may not cause harmful interference.
This device must accept any interference received, including inter-
This device may not cause harmful interference.
This device must accept any interference received, including inter-
ference that may cause undesired operation.
Changes or modifications not expressly approved by the party
Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to
operate the equipment.
FCC ID: B4Z-914E-DWS
IC: 1175C-914EDWS
FCC ID: B4Z-914E-DWS
IC: 1175C-914EDWS
Technical support
Toll-free: 888.GESECURity (888.437.3287 in the US, including Alaska and Hawaii; Puerto Rico; Canada).
Outside the toll-free area: Contact your local dealer.