UTC Fire & Security Americas Corporation Inc 914E-DWS User Manual

Page of 3
3
External contact wiring
Use the following specifications for the external contact:
• Maximum wire length: 26 ft. (8 m).
• Wire: Stranded, 22-gauge (0.7112 mm).
• Switches: Hermetically sealed external switches (sealed 
reed switches) that supply a minimum 250 ms open or close 
on alarm.
Note:  Do not connect more than five external contacts to a door/
window sensor.
You can wire the sensor terminal blocks with leads from an 
external contact (Figure 8). The door/window sensor provides 
alarm and tamper indication. Wire the external contact with one 
end-of-line (EOL) resistor in series with the external contact. 
This gives the following readings for each configuration:
Figure 8 shows external contact wiring (normally closed and 
normally open).
Figure 8. External contact wiring
Sensor test
The sensor test verifies proper communication between the 
sensor and the panel/receiver. To test the sensor, refer to the 
specific panel/receiver documentation and do the following:
1.
Put the panel/receiver into sensor test mode.
2.
Open the door/window the sensor is protecting. The sensor 
transmits a signal.
3.
Listen for siren beeps to determine the appropriate response.
4.
Exit sensor test mode.
Battery replacement
When the system indicates low sensor battery, replace it immedi-
ately. Use the recommended replacement batteries (see 
).
To replace the batteries:
1.
Remove the sensor cover.
2.
Remove the battery. Follow local laws for battery disposal.
3.
Insert the replacement battery, observing correct polarity 
(Figure 3 on page 1).
4.
Perform a sensor test with the panel. See 
.
Specifications
CAUTION:  You must install the EOL resistor at the 
external detection device for proper supervision.
Normally closed
Zero ohm/short = Tamper
4.7 Kohm = Normal
Open = Alarm
Normally open
Zero ohm/short = Tamper
4.7 Kohm = Alarm
Open = Normal
Door/Window
Contacts
EOL resistor
     Sensor
  4.7 Kohm
Model number
Brown: 60-362N-11-319.5
White: 60-362N-10-319.5
Frequency
319.5 MHz
Compatibility
GE Security 319.5 MHz control panels/
receivers
Battery type
3.0 V, 1300 mAh lithium
Required batteries
Duracell DL 123A, Panasonic CR123A, Sanyo 
CR123A, Varta CR123A
Estimated battery life
5 to 10 years at 20°C (68°F) depending on the 
number of activations per day
Magnet gap
3/8 in. (max.)
Supervisory interval
64 minutes
End-of-line resistor
4.7 Kohm
Typical RF output power
0.25mW EIRP
Operating temperature
10 to 120°F (-12 to 49°C)
Storage temperature
-30 to 140°F (-34 to 60°C)
Relative humidity
0 to 90% noncondensing
Dimensions (L x W x D)
3.02 x 1.5 x 1.02in. (81 x 38 x 26 mm)
Weight
44 g
Listings
UL 1023, UL 1610
FCC
This device complies with part 15 of the FCC rules. Operation is 
subject to the following conditions: 
This device may not cause harmful interference. 
This device must accept any interference received, including inter-
ference that may cause undesired operation. 
Changes or modifications not expressly approved by the party 
responsible for compliance could void the user’s authority to 
operate the equipment. 
FCC ID: B4Z-914E-DWS
IC: 1175C-914EDWS