UTC Fire & Security Americas Corporation Inc 983-UDWS User Manual

Page of 2
 
P/N 466-4430 
• REV A.09 • 24Jul13 
1 / 2 
 
Micro Door/Window Sensor Installation Sheet 
Description 
The Micro Door/Window Sensor is a 
supervised, wireless sensor that detects the 
opening and closing of doors, windows, or 
drawers. The sensor and magnet are mounted 
using double-sided adhesive tape or screws 
(included). 
When activated, the sensor transmits an open 
(trip) or close (restore) signal to the panel. 
These are the signals the unit provides: 
supervisory, tamper and low battery (as 
needed). 
The sensor is powered by a replaceable 3-
VDC, lithium coin-cell battery.  
Installation guidelines 
• 
Mounting the sensor on metal can reduce 
its transmitting range. Therefore, test the 
sensor from the desired location using the 
dealer sensor test, before permanently 
mounting it. 
• 
Mount the sensor within 100 ft. of the 
panel. 
• 
Mount the sensor on the frame, and the 
magnet on the door, window, or drawer. If 
mounting on double doors, mount the 
sensor on the least used door and the 
magnet on the other door. 
• 
Mount sensors at least 5 inches above the 
floor to avoid damaging them. 
Programming 
The following steps describe the general 
guidelines for programming (learning) the 
sensor into panel memory. Refer to the 
specific panel’s documentation for complete 
programming details. 
 
1. 
Set the panel to the program mode. 
2. 
Proceed to the LEARN SENSORS menu. 
3.   Select the appropriate sensor group and 
sensor number assignments. 
4. 
When prompted by the  
panel to trip the sensor  
for learning, remove the 
battery pull tab or remove 
the sensor cover. The  
system should  
acknowledge learning  
the sensor by touchpad  
display and/or audio  
(depending on the panel).  
5. 
Exit program mode. 
Testing the sensor 
1. 
Set the panel to the sensor test mode. 
2. 
Take the sensor and magnet to the 
desired mounting location, making sure to 
line up their alignment marks with each 
other. 
3. 
Trip the sensor by pulling the magnet 
away from the sensor. 
4. 
Listen for the system siren beeps to 
determine the appropriate response and 
refer to the specific panel documentation. 
Mounting the sensor 
Mount the sensor after successful programming 
and testing are completed, using the supplied 
mounting screws for all UL installations. For non-
UL installations, using the supplied double-sided 
tape is optional. 
Note: The gap between the 
sensor and magnet should be a maximum of 
3/8”.
 
Mounting screws (UL Installations) 
1. 
Remove the sensor base from the sensor.  
2. 
Place the sensor base in desired location 
and mount the base with the supplied 
screws. Attach the sensor to the base.