UTC Fire & Security Americas Corporation Inc 983-UDWS User Manual

Page of 2
 
2 / 2 
Micro Door/Window Sensor Installation Instructions 
3. 
Mount the magnet into the desired 
location using the supplied screw and lock 
washer, making sure the alignment mark 
lines up with the sensor’s.  
Double-sided tape (optional for non-UL 
installations) 
1. 
Before applying double-sided tape, 
ensure that the desired location is a 
smooth, clean and dry surface. 
 
Note: When applying the double-sided 
tape, evenly apply pressure to ensure a 
good surface contact.  
2. 
Apply double-sided tape to the bottom of 
the sensor and the magnet. Mount the 
sensor and magnet at the desired 
locations, ensuring the alignment marks 
line up with each other.  
3. 
Retest the sensor using the procedure in 
the section “Testing the Sensor”. 
For additional tamper security 
1. 
Punch out the seal covering the screw 
hole on the sensor cover. 
2. 
With the sensor base secured to the 
sensor, insert the smallest screw 
supplied, securing the sensor base to the 
sensor.  
Replacing the battery 
1. 
Remove the sensor from the base then 
remove the inner cover, exposing the 
battery.  
2. 
Remove the bad battery and install the 
new battery. NOTE: Observe polarity of 
the battery. 
3. 
Re-install the PC board, inner cover and 
the sensor. 
Specifications 
Model no. 
TX-1012-01-1 (white) 
TX-1012-01-3 (brown) 
RF frequency 
319.5 MHz 
Compatibility 
Interlogix Learn Mode Panels 
and Receivers 
Battery type 
3-VDC, lithium coin-cell battery 
UL Approved Battery 
Duracell DL2032 
Varta CR2032 
Panasonic CR2032 
Operating 
temperature range 
32 to 120°F (0 to 49°C) 
Storage temperature 
range 
-30 to 140°F (-34 to 60°C) 
Relative humidity 
0-85% non-condensing 
Dimensions  
(L x W x D) 
1.9 x 1.0 x 0.50 in. (4.7 x 2.5 x 
1.3 cm) 
Regulatory information 
Manufacturer 
UTC Fire & Security Americas 
Corporation, Inc. 
1275 Red Fox Rd., Arden Hills, MN 
55112-6943, USA 
FCC 
compliance 
This device complies with part 15 of 
the FCC Rules. Operation is subject to 
the following two conditions: (1) This 
device may not cause harmful 
interference, and (2) this device must 
accept any interference received, 
including interference that may cause 
undesired operation. 
FCC ID: B4Z-983-UDWS 
IC: 1175C-983UDWS 
This Class B digital apparatus 
complies with Canadian ICES-003. 
Cet appareil numérique de la classe B 
est conforme à la norme NMB-003 du 
Canada. 
 
UL 
ANSI/UL 634 Connectors and 
Switches for Use with Burglar-Alarm 
Systems 
UL 1023 
– Household Burglar-Alarm 
System Units.  
ULC 
C634-M1986 - Connectors and 
Switches for Use with Burglar-Alarm 
Systems 
Contact information 
For contact information, see 
 or call +1 855 286 8889. 
Trademark/Copyright 
© 2013 UTC Fire & Security Americas 
Corporation, Inc. Interlogix is part of UTC 
Climate Controls & Security, a unit of United 
Technologies Corporation. All rights reserved.