Battery replacement
When the system indicates the sensor battery is low, replace it 
immediately. Use the recommended replacement batteries (see 
) or contact technical support for more information.
To replace the batteries, do the following:
1.
To remove the sensor cover, press a small flathead screw-
driver into the slot on both sides of the sensor and turn the 
screwdriver 90 degrees. This will disengage the clips 
holding the cover and base (Figure 1 on page 1).
2.
Place a small flathead screwdriver in the slot between the 
metal clip and the battery and twist the screwdriver slightly 
while holding back one of the black plastic edges holding the 
battery. Dispose of the old battery as required by local laws.
3.
Insert the replacement battery with the + sign facing out.
4.
Verify programming and RF communication with the panel. 
Se
External contact
The sensor ships with a six-inch external contact lead. To use the 
external contact, open the transmitter, plug in the external contact 
header (J1), and connect the brown and blue leads to the external 
contact.
Note:  
The external wire cannot be longer than 3.3 ft. (1 m).
FCC compliance
This device complies with part 15 of the FCC rules. Operation is subject to the 
following conditions: 
1. This device may not cause harmful interference. 
2. This device must accept any interference received, including interference 
that may cause undesired operation. 
Changes or modifications not expressly approved by the party responsible for 
compliance could void the user’s authority to operate the equipment. 
FCC ID: B4Z-TX-1010-01
Industry Canada ID: 1175C-TX101001
Specifications
 
Battery
Panasonic 2032, 3 VDC, 225 mAh, lithium 
coin battery (5-year typical battery life)
Transmitter frequency
319.508 MHz (crystal controlled)
Transmitter frequency tolerance ± 8 kHz
Transmitter bandwidth
24 kHz
Modulation type
Amplitude shift key (ASK)
Unique ID codes
16 million
Peak field strength
Typical 30,000 uV/m at 3m
External input sampling current 20 uA
Reed switch magnetic sensitivity 10 to 20 amp turns
Reed sensitivity
0.38-in. (0.97-cm) gap
Magnet type
Nd-Fe-B, N45
Magnet dimensions (WxHxD)
1.3 x 0.435 x 0.312 in. (3.3 x 1.1x 0.79 cm)
Supervisory interval
64 minutes
Operating temperature
10 to 120°F (-12 to 49°C)
Enclosure
PC-540
Weight
0.55 oz. (15 g)
Dimensions  (WxHxD)
1.00 x 2.45 x 0.35 in. (2.54 x 6.22 x 0.89 cm)
Colors
White or brown
Technical support
Toll-free: 888.GESECURity (888.437.3287 in the US, including Alaska and Hawaii; Puerto Rico; Canada). 
Outside the toll-free area: Contact your local dealer.