Andrew Wireless Innovations Group BCEL-FAST719 User Manual
MN021-01
Page 14 of 28
8. Troubleshooting
ALARM DESCRIPTION
LED
STATUS SEVERITY
ACTION
UL AGC out of range
RU1, 2, 3, or 4
Flashing
MINOR
Optical power below –4dBm:
check for fiber or splices
stresses, clean optical
connectors
check for fiber or splices
stresses, clean optical
connectors
UL optical power too low
RU1, 2, 3, or 4
Fixed
MAJOR
Low optical power below –6
dBm: check for fiber or splices
stresses, clean optical
connectors
dBm: check for fiber or splices
stresses, clean optical
connectors
If TFAF has faulty laser,
replace TFAF
replace TFAF
DL laser optical power too low
LU
Fixed
MAJOR
Laser failure: replace TFLF
UL RF amplifier
LU
Fixed
MAJOR
Internal failure: replace TFLF
DL RF amplifier
LU
Fixed
MAJOR
Internal failure: replace TFLF
Temperature alarm
LU
Flashing
MINOR
External temperature too high:
check air circulation
check air circulation
Supply alarm
LU
Fixed
MAJOR
Internal failure: replace TFLF
REMOTE UNIT ALARM DESCRIPTION
DL AGC out of range
RU1, 2, 3, or 4
Flashing
MINOR
Optical power below –4dBm:
check for fiber or splices
stresses, clean optical
connectors
check for fiber or splices
stresses, clean optical
connectors
DL optical power too low
RU1, 2, 3, or 4
Fixed
MAJOR
Optical power below –6dBm:
check for fiber or splices
stresses, clean optical
connectors
check for fiber or splices
stresses, clean optical
connectors
DL RF amplifier 1
RU1, 2, 3, or 4
Fixed
MAJOR
Internal failure: replace TFAF
DL RF amplifier 2
RU1, 2, 3, or 4
Fixed
MAJOR
Internal failure: replace TFAF
Antenna disconnected
(DC loop)
RU1, 2, 3, or 4
Flashing
MINOR
Antenna cable probably broken
or disconnected.
or disconnected.
Antenna connected to TFAF
doesn’t support DC-loopà see
store procedure to mask
unwanted alarm
doesn’t support DC-loopà see
store procedure to mask
unwanted alarm
External 1
RU1, 2, 3, or 4
Fixed
MAJOR
External alarm 1
External 2
RU1, 2, 3, or 4
Fixed
MAJOR
External alarm 2
NOTE: All major alarms will trigger the dry contacts to “closed” status.