8. Troubleshooting 
 
 
 
 
 
ALARM DESCRIPTION 
LED 
STATUS  SEVERITY 
ACTION 
UL AGC out of range 
RU1, 2, 3, or 4 
Flashing 
MINOR 
Optical power below –4dBm: 
check for fiber or splices 
stresses, clean optical 
connectors 
UL optical power too low  
RU1, 2, 3, or 4 
Fixed 
MAJOR 
Low optical power below –6 
dBm: check for fiber or splices 
stresses, clean optical 
connectors 
If TFAF has faulty laser, 
replace TFAF 
DL laser optical power too low  
LU 
Fixed 
MAJOR 
Laser failure: replace TFLF 
UL RF amplifier  
LU 
Fixed 
MAJOR 
Internal failure: replace TFLF 
DL RF amplifier  
LU 
Fixed 
MAJOR 
Internal failure: replace TFLF 
Temperature alarm 
LU 
Flashing 
MINOR 
External temperature too high: 
check air circulation 
Supply alarm 
LU 
Fixed 
MAJOR 
Internal failure: replace TFLF 
REMOTE UNIT ALARM DESCRIPTION 
DL AGC out of range 
RU1, 2, 3, or 4 
Flashing 
MINOR 
Optical power  below –4dBm: 
check for fiber or splices 
stresses, clean optical 
connectors 
DL optical power too low  
RU1, 2, 3, or 4 
Fixed 
MAJOR 
Optical power below –6dBm: 
check for fiber or splices 
stresses, clean optical 
connectors 
DL RF amplifier 1  
RU1, 2, 3, or 4 
Fixed 
MAJOR 
Internal failure: replace TFAF 
DL RF amplifier 2  
RU1, 2, 3, or 4 
Fixed 
MAJOR 
Internal failure: replace TFAF 
Antenna disconnected 
 (DC loop) 
RU1, 2, 3, or 4 
Flashing 
MINOR 
Antenna cable probably broken 
or disconnected. 
Antenna connected to TFAF 
doesn’t support DC-loopà see 
store procedure to mask 
unwanted alarm 
External 1 
RU1, 2, 3, or 4 
Fixed 
MAJOR 
External alarm 1 
External 2 
RU1, 2, 3, or 4 
Fixed 
MAJOR 
External alarm 2 
 
NOTE: All major alarms will trigger the dry contacts to “closed” status.