Andrew Wireless Innovations Group BCEL-FAST719 User Manual

Page of 30
 
MN021-01 
Page 16  of 28
 
 
10. Functional description 
10.1.  
Block diagram 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 11  Remote Unit TFAF Block Diagram 
10.2.  
Up link operations 
Low noise amplification: the low level signal coming from the antenna and duplexer is amplified 
and filtered.  
 
E/O Conversion
: The RF signal modulates the intensity of an optical carrier through an electro-
optic device (laser).  
10.3.  
Down link operations 
O/E Conversion: The modulated optical signal coming from the local units is detected and 
demodulated back to electrical signal. 
 
Amplification & AGC
: Variable amplification is needed to compensate for the variable optical 
fibre loss, maintaining a good signal to noise ratio, to maintain a constant gain for each link. The 
resultant signal is amplified, filtered and is duplexed to feed the antenna. 
10.4.  
Remote supply 
The remote unit is powered with  –48VDC supply, positive to GROUND, by means of composite 
copper wire and fibre cable.  
10.5.  
Automatic Gain Control  
Optical link losses are typically related to: 
 
• 
Fibre length (0.2-0.4dB/Km @ 1300nm) 
• 
Splices loss 
• 
Optical connectors tolerances and aging 
 
BriteCell™  Fast implements an automatic gain control (AGC) mechanism to maintain constant 
RF link gain, regardless of the overall optical link losses.  The allowed optical loss per link must 
be in the range of 3dB.  Losses outside this window will trigger alarms and warnings according 
to the following table: 
DC     DC                -48VDC 
PHOTODETECTO
 
Downlink 
AGC 
VARIABLE 
GAIN AMP. 


DD 
µ
PROC
.  
Diff. AMP 
LASER module
MONITOR PHOTODET. 
LASER DIODE 
VOLTAGE 
CONTROLLED 
ATTENUATOR 
MATCHING 
NETWORK 
UL  ATTENUATOR CONTROL 
SWITCHES 
attenuator 
control 
voltage 
DL final amplifier stage 
current monitor
RF 
SMA  
RF SMA 
50 
Ω
 
Data link  
DC/DC 
converter 
Voltage 
Regulator  
RX optical power monitor 
 
Shut down 
control 
CURRENT 
GENERATOR 
LASER control 
module 
+12 V
-8 V
+5 V
Auxilliary External
alarms 
DC loop