Andrew Wireless Innovations Group RPT-MR703P User Manual

Page of 59
U
SER
´
S MANUAL FOR BAND SELECTIVE REPEATERS 
MR
X
03P 
 
 
User'sManual.doc 
Id.-No.:154999 
Page 18 
22-Jan-01 
 
3.  OPTIONAL EQUIPMENT 
 
The actual repeater configuration can be seen at the configuration list which is part of 
the delivery. 
 
3.1. 
MODEM 
 
The modem option enables the provider to set parameters and to query the status of 
each repeater remotely. Furthermore, the modem can be set to send all occurred 
alarms of the repeater directly to a provider’s terminal, e.g. to the OMC. This can be 
done either via a wireless modem or a PSTN modem (Public Switched Telephone 
Network). Thus, the alarms can be evaluated and eliminated promptly. It is possible 
to install the wireless modem or the PSTN modem on site! 
 
 
Check the communication mode between the modem and the terminal. If 
necessary, set the following parameters: 
 
Bit rate / bit per second: 
9600 baud 
Number of data bit:   
8 bit 
Parity bit: 
 
 
No parity 
Stopbit: 
 
 
1 stopbit 
 
These settings can only be changed after connection to the terminal. If a different 
modem is required or if the quality of the line does not allow to use the set 
parameters, the settings have to be changed in PC mode. The same applies for all 
other parameters which can be set previously for modem mode by software. 
 
3.1.1.  Initstrings 
 
Depending on the provider’s network and the  used modem type, it is necessary to 
adjust the initstring. The following initstrings are factory set: 
 
Modem 
Network 
Initstring 
Siemens M1* 
GSM900 
ATE0S7=60S0=2\N6 
Siemens M20* 
GSM900 
ATZE0S0=2&S0+IFC=0,0+CBST=7,0,1 
Motorola Mobile 
MR30 “Surf–Pro”** 
PCS1900 
AT*P1&F&K4E0S0=2\N0+CBST=7,0,1 
MIKOM MO4000 
GSM900/1800 
ATE0S7=60S0=2;+CBST=7,0,1 
PCMCIA-modem 
PSTN 
AT&FE0S0=2 
The Siemens M1 modem is no longer available and is replaced by the Siemens M20. In future, it is 
assigned to replace all wireless modems working in GSM900/GSM1800 networks by the new MIKOM 
modem MO4000.
 
**
in connection with Cellect2 Card 
table 3-1 Standard initstrings for modems 
 
For further details to the initstrings, please refer to the user’s software manual.