Noise Reduction Techniques
3.
Ignition Switch
4.
Lamp bulbs (headlamps, tail lamps, dome lamps, etc.)
5.
Accessory wiring (electrical fuel pump, electric windshield wipers, heater fan motor, window 
openers, etc.)
10.7
Ground Bonding
If a vehicle is not properly bonded to ground, static charges can increase. This increase can cause 
noise from electrical arcing. This type of noise is suppressed by bonding the part using one-inch wide 
ground straps (keep them as short as possible). Some common points where bonding may be helpful 
are listed below (see Figure 10-5).
A. From engine block to the firewall.
B. From engine block to vehicle frame at points where the engine is shock-mounted.
C. From the battery ground terminal to the vehicle body.
D. From top of front wheel “A” frames to chassis, particularly in cases where rubber-mounted 
members are used.
Figure 10-5.
Ground Bonding
Battery
Firewall
Chassis
Fender
Well
Front Wheel
"A" Frame
B
A
C
D
D