Fibar Group S.A. FGS223 User Manual

Page of 26
10
OPERATInG THE DEVICE
Resetting the Switch 2: 
1.  Switch off the mains voltage (disable the fuse).
2.  Remove the Switch 2 from the wall switch box.
3.  Switch on the mains voltage.
4.  Press and hold the B-button to enter the menu.
5.  Wait for the visual lED indicator to glow yellow.
6.  Quickly release and click the B-button again.
7.  After few seconds the device will be restarted, which is signalled 
with the red lED indicator colour.
NOTE
Resetting the device is 
not the recommend-
ed way of removing 
the device from the 
Z-Wave network. use 
reset procedure only 
if the primary con-
troller is missing or 
inoperable. Certain 
device removal can be 
achieved by the pro-
cedure of removing 
i
Menu allows to perform Z-Wave network actions. In order to use the 
menu:
1.  Switch off the mains voltage (disable the fuse).
2.  Remove the Switch 2 from the wall switch box.
3.  Switch on the mains voltage.
4.  Press and hold the B-button to enter the menu.
5.  Wait for the lED to indicate the desired menu position with colour:
•   GREEN - reset energy consumption memory
•  VIOLET - start range test
•  YELLOW - reset the device
6.  Quickly release and click the B-button again.
Controlling the Switch 2 using the B-button: 
The Switch 2 is equipped with a B-button, which allows to use the 
menu and perform the following actions:
1x click:
•  Cancel alarm mode (flashing alarm).
•  Select desired menu position (if menu is active).
•  Exit range test.
•  Turn 1st channel On/OFF.
3x click:
•  Send the node Info Z-Wave command frame (adding/removing).
Hold:
•  Enter the menu (confirmed by the lED indicator).