CBF Networks Inc. dba Fastback Networks 107 User Manual

Page of 21
IBR Installation Guide 
 
Page 18 of 21 
Doc # 770-00033.0 
 
 
Jan. 22, 2016 
                        1.  
        2.  
    
               3.  
      4.  
     5.  
 
  These are the steps to properly crimp a shielded connector as shown in the photos above: 
1)  Strip away about 2-3” of the outer jacket, but do not cut the drain wire.  Arrange and flatten the wires 
in the following order: orange stripe, orange solid, green stripe, blue solid, blue stripe, green solid, 
brown stripe, brown solid.  Clip the wires so there is ½” distance between the end of the wires and 
the black wire jacket.  
2)  Assemble the connector with the clip side down onto to the wires.  Push the wires into the connector 
so that the ends of all 8 wires make contact with the end of the connector.   Crimp the RJ-45 with 2-3" 
of drain wire pulled back for termination. 
3)  Thread the drain wire through the metal insulator on the connector.  You may need to pry the metal 
insulator back a bit with a pocket knife in order to thread the wire through.  This ensures a good 
mechanical connection.  Push the metal insulator back into place after threading the ground wire 
through it. 
4)  Snip off the excess drain wire. 
5)  Complete the termination: 
a.  If using a surge suppressor with a ground bus such as the Transector 1101-778, ground drain 
wires at the other end of the cable to the surge protector ground bus. 
b.  If using a surge suppressor with RJ-45 jacks such as Microsemi PD-OUT/SP11 or Transector 
1101-959, ground the drain wire as shown above. 
5.6 
Surge Suppressor Installation 
Surge suppressor(s) should be installed for all metallic cables that penetrate a building or equipment 
enclosure. These devices should be mounted near the cable penetration point(s).   
For PoE
+
 implementations and other CAT5e/CAT6 cables and for AC power wiring, surge suppressors are 
essential for network equipment and human safety.  
Fiber cables do not require surge protection. 
A second (set of) surge suppressor(s), connected, mounted and grounded very near the IBR, is/are strongly 
recommended for long-cable installations and/or regions with a high incidence of lightning.