Unique Broadband Systems Ltd. DRU1KW User Manual

Page of 176
 
 Chapter 
Maintenance 
 
6.5.5 
Terrestrial Repeater Monitoring System (TRMS) Replacement 
 
 
Always ensure that the AC power to the TRMS has been switched OFF 
prior to removing the TRMS.  This will prevent injury caused by electric 
shock and prevent damage to equipment. 
 
 
6.5.5.1 
TRMS Removal 
 
The TRMS should be removed in the following sequence: 
 
1.  Open the LB cabinet electronics compartment front and rear doors, as well as the HB 
cabinet front door. 
2.  Switch OFF the TRMS rear panel power switch. 
3.  Switch OFF the TRMS circuit breaker (CB 8), located on the LB cabinet PDU front 
panel. 
4.  Disconnect the wires/cables connected to the TRMS rear panel. 
5. 
Remove the four (4) Phillips pan head screws which secure the TRMS to the mounting 
rails 
6.  Remove the TRMS from the LB cabinet electronics compartment and set it aside. 
 
Figure 6-7 TRMS in Rack 
 
 
1)  XXX Screw 
2)  TRMS 
 
 
 
 
 
 
 
 
 
 
 
SX03-20000-01-M01 6-19