3.10.2  High Band Exciter (HBE) 
 
During the installation procedure, a number of wires/cables must be connected to the HBE 
rear panel.  Please refer to Table 3-6 or drawing SX03-21900-02-D06. 
 
The cables should be connected in the order that they appear in Table 3-6
 
 
Any RF cable, which is terminated with a SMA connector, should be 
tightened with a 5/16” torque wrench to avoid over tightening and 
damaging the cable connector or mating connector. 
 
Figure 3-27 HBE Rear Panel 
 
 
 
Table 3-6 HBE Rear Panel Connections 
HBE Port 
Name 
Type 
Cable Number 
N/A N/A  Ground 
Post 
SX03-21916-05 
CJ02 TEMP 
SENSORS 
DB-25 (F) 
SX03-21905-01 
CJ03 HPA/KPA1 
DB-9 
(F) 
SX03-21906-01 
CP02 
OPA DC PS 
DB-25 (M) 
SX03-10919-01 
RJ02 WAN  RJ-45 
SX03-22905-02 
RJ03 LAN  RJ-45 
SX03-22905-03 
DJ06 
LNA PWR 
4-pos CPC 
SX03-10902-01 
CJ08 DC 
POWER 
14-pos 
CPC 
SX03-10903-01 
DJ02 
RF IN 
SMA (F), 50 ohm 
SX03-10909-02 
DJ05 
ANC IN 
SMA (F), 50 ohm 
SX03-21917-06 
DJ03 
RF OUT 
SMA (F), 50 ohm 
SX03-21917-01 
 