Commissioning 
 
Figure 4-3 LBE GUI sys Page 
 
 
 
4.4.4.2 
High Band Sub-system 
 
Once the HBE is powered up and all alarms have cleared, the operator can place the HB 
repeater in broadcast mode as follows: 
 
1.  Set SysPowerSetp to the site specific power level (max. 53.0 dBm) – see Figure 4-4
config  window  line  4.    SysPowerSetp  is  used to set the power level for the HB RF 
signal. 
2.  Ensure that SysOfnLoss is set to 0.0 dBm – see Figure 4-4, config window line 5. 
3.  Set SysOperatingMode to broadcast – see Figure 4-4, config window line 1.  
SysOperatingMode is used to set the HB sub-system operating mode. 
o
 
Ensure that the LNA LED is illuminated green. 
o
 
The LED’s on the HB HPA’s will flash green and blue alternately as the HPA’s ramp 
up to the SysPowerSetp target. 
o
 
Once the SysPowerSetp target is reached, the HPA LED’s will be illuminated green.  
It should take less than 2 minutes for the HB sub-system to ramp up to full power. 
4.  Ensure that the SysPowerSetp target is reached by viewing the Cpl1ForwardPwr – see 
Figure 4-3, status window line 10. 
o
 
Note: The HBE GUI does not provide any coupler measurements.  The combined 
(coupler 1) and independent (coupler 2) coupler measurements are provided by 
the LBE GUI. 
5.  Ensure that the TRMS HB Status LED is illuminated green. 
o
 
The TRMS should scan through the channels at a fast rate of approximately 2 
seconds per channel. 
 
SX03-20000-01-M01 4-9