How the communication network must be configured in order for the beacons to be able to 
communicate with the location server is also described in this document. 
5. Wiring Installation 
5.1. Plans with the position of the net sockets 
The installation team is provided with the building plans in which the positions of the net 
sockets are marked. Figure 1 shows a piece of a plan. The red round symbols mark the 
position in which each beacon must be placed. The blue square symbols depict additional 
net sockets that are not intended for beacons, but for PCs or TVs 
 
 
Figure 1 
– Example of a plan; in red the beacons, in blue socket for TV or PC 
 
The plan can be divided in several files, each of them with a section of the area to install. 
Each  of  the  fragments  of  the  plan  must  be  printed,  as  they  are  intended  to  be  used  to 
note down by hand the following data: 
Name of the net socket (it normally corresponds with the patch panel port). 
Serial number of the beacon placed in that position (figure 1). 
5.2. Wiring category 
In case it is necessary to install new wiring, the cables to use must be at least UTP Cat 6 
free  of  halogens. The  lengths  and  placement  of the  cables  must follow  the  regulation  of 
the structured cabling standards. 
In case there is a previous cabling installation, the beacon is able to operate with cables of 
Cat 3 or higher. 
5.3. Wiring installation 
A net socket will be installed in each of the positions shown in the plan. Once installed, the 
net  socket  identifier  must  be  noted  down  on  the  printed  plan.  The  identifier  of  the  net 
socket will follow the format used in the client’s network.