5
3. Wire terminal diagram
Initialization
Please insert the prepaid SIM card carefully at the back of main panel,and then plug in AC
power.( If you want to recharge the back up battery, you need to switch on firstly and then
plug in AC power)
The LCD display will show [F5]→[F6]→[Signal strength ] one by one after you power on
the system. It means the system is connected to GSM network. And the GSM LED
indicator will flash slowly 1 time every 3 seconds
System setting
All the settings can be carried out under the disarmed status with a long ‘DI’
for all the proper operations. while two short sounds for wrong settings
1.External siren volume adjustment
Under the disarm status, User can program the following command to adjust
the volume of siren. The X is bigger, the sound will be bigger too.Finally
press [#] again to end this operation. You will hear a long ‘DI’ sound to show
correct setting.
Command:[#]→[0]→[X]→[#]
X=1-9: External siren sound will be bigger for bigger number
X=0: External siren sound will be off
2. Human voice on or off
User can close or open the human voice reminder as per your needs.
Command:[*]→[0]→[4]→[X]→[*]
X=1: Voice will be off
X=0: Voice will be on
3.Tone of arm and disarm setting
The external siren will give off response tone for each arm and disarm
Command:[*]→[2]→[X]→[*]
X=1: Enable siren response for arming and disarming
X=0: Disable siren response for arming and disarming