RF Engineering & Energy Resource LLC KI-GSM904 User Manual

Page of 21
8
Example: If you want to zone 15 to be home alarm type: [#]→[8]→[15]→[2]→[#]
Inactive zone: The zone will be closed
Burglarproof alarm zone: The sensors will trigger alarm under arming status, but it won’t
trigger Alarm under disarming status
Emergency alarm zone: No matter when the system is armed or disarmed, the sensors
at emergency zone will trigger alarm. Which is mainly for smoke
sensor, gas sensor, panic button etc
Home arm zone: The sensors at home arm zone won’t trigger alarm under the home arm
status, but other sensors will trigger alarm as normal
Multi checked zone: Only 2 or more sensors at the same zone are triggered within 30
seconds, it will trigger alarm
Delay alarm zone: The alarm only be started in the preset delayed time after triggered
Double trigger zone: It will alarm when the sensor is triggered twice within 5-30 seconds,
otherwise it won’t give off alarm
Doorbell: It won’t give off alarm but “ding dong” doorbell sound for each trigger
10.Delay alarm time setting
The alarm will start after delayed time you set
Command:[#]→[7]→[A]→[#]
A=0-99 seconds, max 99 seconds
11.Delay arm time setting
The system will be armed automatically after delayed time you set after
press arm button of remote control or main panel
Command:[*]→[4]→[A]→[#]
A=0-99 seconds, max 99 seconds
Note: If you press ARM button twice, the system will be armed quickly without delay
12.Password protection enabled
The panel will be protected by operation password in 26 seconds once
you enable this function
Command: [*]→[1]→[1]→[*]
13.Password protection disabled
The panel won’t be protected by operation password once you disable
this function
Command: [*]→[1]→[0]→[*]
14.Operation Password
The panel will require user to input password before any operation if user
enable the password protection
Command:[*]→[A]→[*]
A=password, 4 digits. The defaulted password is 0000