Coarse Wavelength Division Multiplexing
Optical Insertion Losses
The following Sections present examples of Optical Insertion Loss estimation with calculations, in tabular form. A simple diagram is included for
each example.
Each diagram displays the logical device-paths used for Optical Insertion Loss calculations through each stage of Canary Multiplexer / De-
Multiplexers (four & eight-channels) and OADMs that service one, two and four Client-channel Drops & Adds (signal reinsertions).
Optical Insertion Loss estimation:
• Example 1 of Origin to Remote-Point (link) Loss Calculation
with no intermediate OADM (client Drop, Add or Pass-Thru) stages
(or their associated OADM Optical Insertion Losses).
• Calculates accumulated typical and maximum path Losses from
Origin to Remote end-point.
• Given: Origin and Remote site Multiplexer/De-Multiplexer losses
(Mux/De-Mux) and no OADMs in the optical path.
• Origin Chassis Multiplexer/De-Multiplexer (CM-4MD6-A)
stage denoted by M
O
  & D
O
  and Remote Mux & De-Mux
(CM-4MD6-A) stage denoted by M
R
 & D
R
Table (C-1)
Insertion Loss: Each
Insertion
Insertion
Insertion
Acc. Loss
Insertion
Insertion
Insertion
Acc. Loss at
Total Loss at end-
Mux + De-Mux stage
Loss (1st)
Loss (1st)
Loss (1st)
at (1st)
Loss (2nd)
Loss (2nd)
Loss (2nd)
(2nd) Drop
point Demux w/ no
(typically at segment
 Drop point
Add point
Pass-Thru
Drop point
Drop point
Add point
Pass-Thru
point
Pass-Thru stages
end-points)
(M
O
 & D
O
)  (M
R
 & D
R
)
(M
O
 + D
R
)
1.2 dB            1.2 dB
None:
None:
None:
None:
None:
None:
None:
None:
(Typical Optical Loss)
No OADM
No OADM
No OADM
No OADM
No OADM
No OADM
No OADM
No OADM
2.4 dB
2.4 dB            2.4 dB
None:
None:
None:
None:
None:
None:
None:
None:
(Maximum Optical Loss)
No OADM
No OADM
No OADM
No OADM
No OADM
No OADM
No OADM
No OADM
4.8 dB